REFRIGERATION AND ELECTRICAL DATA
After 01/01/2020
Model
RSSL678SC
RSSL678R
Power Supply, Volts
208-240 Volts
208-240 Volts
Frequency
60 Hertz
60 Hertz
Phase
1 Phase
1 Phase
Number of Wires
2 + ground
2 + ground
AMPS
VOLTS
AMPS
VOLTS
Compressor
RLA
7.7
208-240
----
----
LRA
54.0
208-240
----
----
Condensar Fan Motor
0.7
208-240
----
----
Evaporator Fan Motor (3)
0.2ea
208-240
0.2ea
208-240
Lights (includes optional
0.3
208-240
0.3
208-240
Shelf lights)
Condensate Pan Heater
5.0
208-240 ----
----
Condensate Pump 0.5 208-240 0.5 208-240
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and
Minimum Circuit Ampacity.
REFRIGERATION
Self-Contained Models
Refrigeration R449a Charge Self Contained
4.25 Pounds
The self-contained models are shipped from the factory with a completely operational R449a
refrigeration system and require no modifications or adjustments upon installation. Case must
be installed as per the installation section of this manual to provide proper condensing air
cooling.
Self-Contained Refrigeration Operation
The unit temperature is controlled by the Electronic control and timers outlined in the control
section of this manual.
Note: The condenser fan runs continuously.
Remote Models
Refrigerant & BTU Requirements
Refrigerant R449A After 01/01/18
10500 BTU’S @20°F Evap/90° Ambient
Refrigerated Self-Serve Merchandiser (High Profile)
Page 26