- 8 -
ELECTRICAL INFORMATION &
GROUNDING
This Case Must Be Grounded
DANGER:
Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
Only a licensed electrician must perform all case electrical connections.
All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
A separate circuit for each display case is recommended to prevent other appliances on the same circuit
from overloading the circuit and causing malfunction.
The electrical service must be grounded upon installation.
Optional Permanent Connected Models,
If this unit is designed for permanent connection to a power source. See the electrical data plate located
at the rear of the case for proper circuit size and wire ampacity.
The electrical connection box is accessible from the rear of the case. Remove rear grill on refrigerated
models. (See “Grill Removal” in the installation section of this manual.) See diagram below for
location of the field wiring connection box.
7/8" DIA. ELECTRICAL ENTRANCE
IN BOTTOM OF CASE,
2-3/4" FROM SIDE OF BASE,
2-1/8" FROM REAR OF BASE.
7/8" DIA. ELECTRICAL ENTRANCE
ON REAR OF CASE,
1" FROM SIDE OF BASE
1-3/4" FROM BOTTOM OF BASE
BACK OF CASE OVERHANGS
BASE 1".
FIELD CONNECTION COVER
FOR REFRIGERATED CASES
E3233-1