290A4605

BI-PIN, #GH-8, #GH-9

Figure 3.

FUNCTION

REPLACEMENT LAMP

Alley, Takedown

50W Halogen, GH-8 (bi-pin)
Part No. 8107169

Primary Strobe

Linear Strobe Tube
Part No. 8583022

Man Down LED

PCB, LED Assy., 2005145

(blue)

Gen-3 LED

Replacement Module
  Amber-Part No. 8583228-02
  Blue-Part No. 8583228-03
  Red-Part No. 8583228-04

Table 2.

-5-

C.

Cleaning Reflector Assemblies.

Use a soft tissue to clean the reflectors.

Avoid heavy pressure and the use of caustic or
petroleum base solvents which will scratch or dull
the surface.

D.

Strobe Tube Replacement.

 WARNING

High voltages are present inside the
lightbar. Wait at least ten (10) minutes,
after shutting off power, before servicing
this unit. Failure to do so may result in
property damage, serious injury, or
death to you or others.

Disconnect ALL power to the lightbar before
any maintenance is performed.

As strobe lights are used, flash tubes begin

to darken, causing the light output to decrease. Also,
as flash tubes age, they may have a tendency to
misfire (not fire periodically).

After extended operation, occasionally

check for flash tube degradation. Should the tube

misfire, have a noticeable decrease in light output,
glow continuously, or darken excessively, it should be
replaced.

NOTE

Not replacing a strobe tube when any of the
above conditions exist could cause a break-
down of other power supply components.

For Primary Linear Strobe Tube replace-

ment, see figure 4 and proceed as follows:

1.

Refer to table 2 for the correct strobe

tube part number.

2.

Remove and retain the screw which

secures the defective strobe head assembly to the
dome. Remove and retain the two screws which
secure the lens to the strobe head assembly.

3.

Insert a small flat head screwdriver in

the slot on the back of the reflector. Note the strobe
tube’s orientation and gently push forward to release
the defective strobe tube.

1   2 3

290A4606

LENS

REFLECTOR

STROBE TUBE

ASSEMBLY

DOME

SCREW

LENS

TRIGGER WIRE

BAND

SCREW, #6 x 3/8"

HI-LO THD. FRM.

PHILLIPS PAN HD. (2)

SCREW, #8-32 x 7/8" MACH.
SLOT IND., HEX WSH. HD. (1)

TO DOME

SLOT

SMALL FLAT

HEAD

SCREWDRIVER

REFLECTOR

Figure 4.

Summary of Contents for Vista

Page 1: ...properly and that it is securely attached to the vehicle File these instructions in a safe place and refer to them when maintaining and or reinstalling the product Failure to follow all safety precaut...

Page 2: ...r proper installation C Function Activation Strobes 1 Mode inputs There are three prioritized modes of operation available with mode three being the highest priority Mode 3 WHT BLU will override Mode...

Page 3: ...the Gray wire Locate the Man Down Backup Feed circuit board Adjust potentiometer R1 clockwise to increase intensity and counter clockwise to decrease intensity Remove 12VDC and reinstall center dome...

Page 4: ...WITH LIGHTBAR POWER IGN TO GROUND 15A 15A 15A 1A 2A 1A 1A 8A 8A 3A 5A 10A 15A 5A GRN ORN GRN GRAY BRN YEL RED RED RED WHT GRN WHT ORG EXTERNAL POWER CABLE WIRE COLOR WHT GRAY WHT RED WHT BLUE WHT BRN...

Page 5: ...sh tubes age they may have a tendency to misfire not fire periodically After extended operation occasionally check for flash tube degradation Should the tube misfire have a noticeable decrease in ligh...

Page 6: ...ay result in property damage serious injury or death to you or others Disconnect ALL power to the lightbar before any maintenance is performed Replace the fuse on the power supply s top with an EXACT...

Page 7: ...injury may result if LED as sembly is touched when hot Always allow LED assembly to cool before removing 1 Man Down LED See figure 5 Refer to table 2 and replace the defective LED assembly with an ex...

Reviews: