WIRING DIAGRAM
(REFER TO NOTE 1)
FROM SEPERATE
SIGNALMASTER CABLE
FLASHING (FLASHER "X")
STROBE PWR SUPPLY FRONT
MODE 3
STROBE PWR SUPPLY REAR
MODE 2
MODE 1
LOW POWER
GND
GND
BACK-UP LOWER LEVEL FLASHERS
REAR LOWER LEVEL FLASHER
FRONT LOWER LEVEL FLASHER
TD/SPOT LIGHT
MAN DOWN
LEFT ALLEY
RIGHT ALLEY
POWER SUPPLY PROGRAMMING
NO CONNECTION
290A4604
INCOMING POWER CABLE
GROUND SCREW
ON EXTRUSION
INTERNAL WIRING
EXTERNAL WIRING
FUSE RATINGS ARE BASED ON A
STANDARD OPTION INSTALLATION.
IF MULTIPLES OF ANY OPTION ARE
INSTALLAED, ADJUST THE FUSE
SIZE AS REQUIRED.
BLK
WHT/GRN
BLK
WHT/ORN
RED
WHT/RED
WHT/BLU
WHT/YEL
ORN
GRAY
BRN
YEL
WHT/BRN
WHT/GRAY
BLU
VIO
WHT/VIO
CUSTOMER SUPPLIED
SUPPLIED WITH LIGHTBAR
(+) POWER/IGN.
(-) TO GROUND
15A
15A
15A
1A
2A
1A
1A
8A
8A
3A
5A
10A
*
*
*
*
*
15A
5A
GRN
ORN
GRN
GRA
Y
BRN
YEL
RED
RED
RED
WHT/GRN
WHT/ORG
EXTERNAL
POWER CABLE
WIRE COLOR
WHT/GRAY
WHT/RED
WHT/BLUE
WHT/BRN
WHT/YEL
WHT/VIO
VIO
BLU
Figure 2.
NOTE 1.
VARIATIONS TO WIRING DIAGRAMS MAY OCCUR WITH SOME OPTION COMBINATIONS. BEFORE CUTTING ANY POWER
CABLE LEADS, PERFORM A FUNCTION CHECK BY APPLYING 12VDC TO THE APPROPRIATE CONTROL LEADS. THE HEAVY
BLACK LEAD (-) MUST BE CONNECTED TO BATTERY GROUND, TO PERFORM A FUNCTION CHECK.
Table 1. Electrical Connections.
Strobe
LED
Man Down
Takedowns and Alleys
BLK
Ground (-)
Ground (-)
RED
Strobe Power Front
-
-
-
WHT/RED
Strobe Power Rear
-
-
-
WHT/BLU
Mode 3
-
-
-
WHT/YEL
Mode 2
-
-
-
WHT/GRY
Mode 1
-
-
-
WHT/ORG
Low Power
-
-
-
VIO
-
Rear
-
-
WHT/VIO
-
Backup
-
-
BLU
-
Front
-
-
YEL
-
-
-
Takedown/Spot Light
GRAY
-
-
Man Down
GRN
-
-
-
Right Alley
ORG
-
-
-
Left Alley
BRN
-
-
-
WHT/BRN
-
-
-
WHT/GRN
-
-
-
Flashing
Wire Color
Functions
(Refer to Note 1)
-4-