Table 6
Auxiliary patterns
Pattern
No.
Description
0
Null (no pattern)
1
Single Alternating 95 FPM *
* Default pattern
2
Single simultaneous 95 FPM
3
Alternating double flash 95 FPM
4
Single alternating 120 FPM
5
Simultaneous double flash 60 FPM
6
All on; for control of external loads only
Table 7
Warn patterns compliant with CAC Title 13, Article 22
Pattern
No.
Description
0
Null (no pattern)
1
Alternating, two-head flash on each end
2
Alternating in/out
3
Alternating odds/evens
Entering Program Mode
With the vehicle ignition turned on and the directional light turned off, press the FAST and LOW buttons
simultaneously (See Figure 5 on page 10). Both buttons remain lit indicating that the controller is now
in Programming Mode. Select one or more of the following features before exiting Program Mode. See
“Exiting Program Mode” at the end of this section.
■
Selecting a Six- or Eight-Head Output
To select a six- or eight-head output for six- or eight-head SignalMasters, press the FAST button
until the correct number of lightheads flashes simultaneously. The indicator LEDs on the controller
mimic the pattern of flashing heads on the SignalMaster.
■
Selecting a Split or Standard Lightbar
To select a split SignalMaster (three- or four-head lightbars) or a standard SignalMaster, press the
LOW button to toggle between split or standard mode.
■
Selecting a Standard Warn Pattern
To select a standard warning pattern, press the WARN button to cycle though the patterns until the
pattern you want appears. For a description of the patterns, see Table 5 on page 10.