Federal Signal Corporation SignalMaster 331105 SMC5 Instructions Manual Download Page 1

Safety Message to Installers and Service Personnel of Warning  
Light Equipment

People’s lives depend on your proper installation and servicing of Federal Signal products. It is important to 
read and follow all instructions shipped with this product and the original product. In addition, listed below 
are some other important safety instructions and precautions you should follow:

•  To properly install this device, you must have a good understanding of automotive electrical procedures 

and systems, along with proficiency in the installation and use of safety warning equipment.

•  DO NOT install equipment or route wiring in the deployment path of an airbag. 

•  If a vehicle seat is temporarily removed, verify with the vehicle manufacturer if the seat needs to be 

recalibrated for proper airbag deployment.

•  When drilling into a vehicle structure, be sure that both sides of the surface are clear of anything that 

could be damaged.

•  In order for the device to function properly, a good ground connection must be made. At a minimum, it 

must be attached to a solid metal body or chassis part that will provide an effective ground path as long 
as the light system is to be used.

•  Locate light control so the VEHICLE and CONTROL can be operated safely under all driving 

conditions.

•  Do not attempt to activate or deactivate light control while driving in a hazardous situation.

•  This product controls high intensity lighting devices. To prevent eye damage, DO NOT stare into the 

light beam at close range.

•  You should frequently inspect the light to ensure that it is operating properly and that it is securely 

attached to the vehicle.

•  File these instructions in a safe place and refer to them when maintaining and/or reinstalling the product.

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death. 

Overview

The Model 331105, SMC5 is a full featured directional light control. It is designed to operate the full 
selection of Federal Signal SignalMaster

®

 directional lights from four to eight heads (continuous or split) at 

12 V or 24 V. High current switching ability allows two full, eight-head, halogen SignalMasters to be directly 
controlled by a single 331105 controller. The controller is protected against reverse polarity by a 2 A fuse and 
a diode. Each SignalMaster lightbar requires an installer-supplied 20 A fuse. 

This model provides six distinctive directional signals. There are standard left-arrow, center-out and right-
arrow patterns as well as special left-arrow, center-out, and right-arrow patterns that comply with CAC Title 
13, Article 22 if used with the appropriate SignalMaster directional lightbar selected from the models in 
Tables 1 and 2 on page 2.

Instructions for the Model 331105 SMC5 

SignalMaster® Lightbar Controller

2562119D  REV. D 911

Summary of Contents for SignalMaster 331105 SMC5

Page 1: ...activate light control while driving in a hazardous situation This product controls high intensity lighting devices To prevent eye damage DO NOT stare into the light beam at close range You should fre...

Page 2: ...r a halogen lightbar The default pattern is the classic SMC warn pattern with the center lightheads alternating with the lightheads on each end The AUX function provides an installer selectable flash...

Page 3: ...2 V SignalMaster at 24 V or a 24 V SignalMaster at 12 V or shortened lamp life will result Model 331105 Controller Specifications Electrical Input Voltage 11 Vdc to 28 Vdc Polarity Negative ground onl...

Page 4: ...not mount the unit near a heater duct NOTE When selecting a mounting location for the control unit it is necessary to keep in mind that some SignalMaster models have cables which are 15 feet long Pla...

Page 5: ...in an electrical fire The controller is equipped with a 15 position connector and two insulated spade connectors Also required are installer supplied red and black wires of the proper gauge for the c...

Page 6: ...d to provide power to two SignalMaster lightbars ensure that the wire is of the recommended gauge for the total load For wire gauge recommendations see Table 4 on page 5 5 Select a termination point f...

Page 7: ...cable to the locations specified in Figure 3 or on the label affixed to the controller housing Figure 3 Wiring from SignalMaster to controller 290A5486C RIGHT TURN SIGNAL INPUT LEFT TURN SIGNAL INPUT...

Page 8: ...cted to a positive voltage source and protected with a fuse Figure 4 Connections for two four head SignalMasters to the controller BROWN FIVE CONDUCTOR CABLE FROM RIGHT SIGNALMASTER 20 A BAT JOIN THE...

Page 9: ...the Turn Signal Override The controller can be connected so that a single end module flashes in sync with the vehicle turn signal If any pattern is displayed when the turn signals are flashing the pa...

Page 10: ...nalMaster Controller on page 13 Figure 5 Model 331105 SMC5 controller 290A5488B FOUR POSITION SLIDE SWITCH AUXILLIARY HEAD LED INDICATORS SIGNALMASTER LED INDICATORS Table 5 Standard warn patterns Pat...

Page 11: ...5 on page 10 Both buttons remain lit indicating that the controller is now in Programming Mode Select one or more of the following features before exiting Program Mode See Exiting Program Mode at the...

Page 12: ...he slide switch to OFF Position 1 and then move it to the LEFT ARROW position Position 2 Exiting Program Mode To exit Programming Mode temporarily interrupt the power to the controller by turning off...

Page 13: ...s a four position switch with OFF and settings for the directional patterns LEFT ARROW CENTER OUT and RIGHT ARROW OFF Position 1 Turns off the directional pattern LEFT ARROW Position 2 Displays a left...

Page 14: ...nal circuit the controller stops any active pattern and flashes the appropriate end lamps in sequence with the turn signals or hazard lights No operator input is needed to activate this feature if con...

Page 15: ...washer Ext Tooth 1 4 7075A007 2 Screw Hex Head 1 4 20 Taptite 7011164 08 Returning a Product to Federal Signal Before returning a product to Federal Signal call 800 264 3578 800 433 9132 or 800 824 02...

Page 16: ...gnal Corporation SignalMaster is a registered trademark of Federal Signal Corp Write the RMA number down so that you can easily check on status of the returned equipment Send all material with the iss...

Reviews: