background image

Handset
Microphone 

 

10 ohm dynamic noise canceling

Receiver 

 

170 +/- 30 ohm high efficiency dynamic

Coil Cord  

 

6 conductor, 10-ft extended

Agency Approvals
UL, cUL 

 

Models SF-1011DT, SF-1015DT, SF-1011P &

   

 

 

SF-1015P are listed for Class I, Div. 2 Grps. A, B, C &

   

 

 

D. Models SF-1231X, SF-1235X, 

   

 

 

SF-1241X & SF-1245X are Listed for use in Class I,

   

 

 

Div. 2; Class II Div 2 Groups F and G, and Class III

   

 

 

Hazardous Locations

BASIC MODEL SPECIFICATIONS

III. INSTALLATION

SAFETY MESSAGE TO INSTALLERS

It is important to follow all instructions shipped with this product. This device is to be installed by a 
trained electrician who is thoroughly familiar with the National Electrical Code and will follow the 
NEC Guidelines as well as local codes.
The selection of the mounting location for the device, its controls, and the routing of the wiring is to be 
accomplished under the direction of the facilities engineer and the safety engineer. In addition, listed 
below are some other important safety instructions and precautions you should follow:
•  Read and understand all instructions before installing or operating this equipment.
•  Disconnect power before connecting or doing any maintenance on this intercom.
•  All effective paging speakers produce loud sounds which may cause, in certain situations, perma-

nent hearing loss. You should take appropriate precautions such as wearing hearing protection.

•  After installation, ensure that all set screws are properly tightened.
•  After installation, test the intercom to ensure that it is operating properly.
•  After testing is complete, provide a copy of this instruction sheet to all operating personnel.
•  Establish a procedure to routinely check the light installation for integrity and proper operation.

Failure to follow all safety precautions and instructions may result in property damage, serious 
injury, or death to you or others.

 

 

Model 

Model 

Model 

Model 

Model 

Model 

Model 

Model

 

SF-1011P  SF-1015P  SF-1011DT  SF-1015DT  SF-1231X  SF-1235X  SF-1241X 

SF-1245X

Description  1 channel  5 channel  1 channel  5 channel  1 channel  5 channel  1 channel 

5 channel

 

panel 

panel 

desktop 

desktop 

wall 

wall 

wall 

wall

 

mount 

mount 

 

 

mount 

mount 

mount 

mount

 

 

 

 

 

indoor 

indoor 

outdoor 

outdoor

Dimensions  9.5 x 7.86  9.5 x 7.86  9.5 x 7.86  9.5 x 7.86  N/A 

N/A 

N/A 

N/A

subset 

x 4 

x 4 

x 4 

x 4

HxWxD in.
Dimensions  3.75 x 6.5  3.75 x 6.5  9.25 x 4.0  9.25 x 4.0  9.5 x 7.86  9.5 x 7.86  16.0 x 13.06  16.0 x 13.06
intercom 

x 6.0 

x 6.0 

x 9.0 

x 9.0 

x 7.7 

x 7.7 

x 8.5 

x 8.5

HxWxD in.
Weight 

16 lbs. 

16 lbs. 

16 lbs. 

16 lbs. 

10 lbs. 

10 lbs. 

19.0 lbs. 

19.2 lbs.

-2-

Summary of Contents for SELECTFONE SF-1011DT

Page 1: ...and shipments to FEDERAL SIGNAL CORPORATION Industrial Systems Service Department 2645 Federal Signal Drive University Park IL 60484 3167 MODEL SELECTFONE INSTRUCTIONS FOR FEDERAL SELECTFONE 2561603B...

Page 2: ...blank page...

Page 3: ...or one hand operation The front panel of each unit features a handset cradle equipped with a contact less sensor to indicate an off hook condition an off hook indicator LED and channel selector switch...

Page 4: ...n this intercom All effective paging speakers produce loud sounds which may cause in certain situations perma nent hearing loss You should take appropriate precautions such as wearing hearing protecti...

Page 5: ...stem is 0 43 11 mm Select the proper conduit size and make no more than two bends for each length as the excessive force required to pull the cable through may damage the insulation 2 Determine the mo...

Page 6: ...wires and cable are free from interference Ensure that the back of the panel is closed 3 Using the template see Figure 3 provided with the panel mount handset assembly make a rectangular cutout in the...

Page 7: ...ed GND at terminal block JP1 of the SelectFone station EQUIPMENT DAMAGE HAZARD No SelectFone station should be installed or operated without having proper ground continuity b 24VDC Power Connection fo...

Page 8: ...ve 14 AWG conductor of incoming and out going power cable to the terminal of JP1 Connect white negative 14 AWG conductor of incoming and out going power cable to the terminal of JP1 Connect the green...

Page 9: ...ted station from announcing the paging messages originated at other stations while channel line conversations are being carried out at the muted station Removing the jumper between IN and OUT terminal...

Page 10: ...by holding a conversation between two or more SelectFone stations on each channel If the line balance assembly is properly connected the speaker should hear little or none of his own voice in the han...

Page 11: ...g system an inoperative station indicates miswiring or a problem with the sta tion itself Check the wiring connection If the problem is not caused by miswiring swap the plug in modules of the effected...

Page 12: ...S Description Part Number Power Supply Module K2001883 Power Supply Module 24VDC K2001883 01 Speaker Amplifier Module K2001882 Speaker Amplifier Module 24VDC K2001897 Handset Pre amp PCBA K2001881 Han...

Page 13: ...sure Mounting Holes PAGE L1 L2 L1 PARTY1 L2 L1 PARTY2 L2 L1 PARTY3 L2 L1 PARTY4 L2 L1 PARTY5 L2 HANDSET C 8 16 IN OUT ISO SPKR MUTE G N D N H A C SLO BLO 1 2 A CN1 PREAMP JP2 CN3 L2 L1 JP1 CN2 8 68 5...

Page 14: ...2 12 KEY A Enclosure Mounting Holes SELECTFONE INDOOR OUTDOOR STATION MODEL SF 1245X SF 1241X FIG 2 6 5 2 1 8 14 6 2 12 6 2 10 00 14 94 290A4034 02 A...

Page 15: ...13 3 PANEL CUT OUT TEMPLATE FOR SF 1015P SF 1011P FIG 3 5 50 3 25 0 25 0 25 290A4034 03 B A KEY A Mounting Holes B Cut Out...

Page 16: ...Y5 L1 L2 PARTY1 PARTY2 PARTY4 PARTY3 L1 L1 L1 L1 L1 L2 L2 L2 PAGE L2 L2 WHITE GRAY WHITE RED AC N H CABLE 2 RED SPEAKER 16 OHM MUTE OUTDOOR WALL MOUNT HANDSET SPEAKER STATION INDOOR PANEL AND DESKTOP...

Page 17: ...ER STATION INDOOR PANEL AND DESKTOP HANDSET SPEAKER SUB STATION 8 CONDUCTOR 120VAC PAIR 14AWG TWISTED PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 430 O D...

Page 18: ...STATION 16 CONDUCTOR 24VDC PAIR 14AWG TWISTED PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 630 O D 2 TO MUTE BETWEEN ANY NUMBER OF STATIONS CONNECT THE A...

Page 19: ...D PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 430 O D 2 TO MUTE BETWEEN ANY NUMBER OF STATIONS CONNECT THE APPLICABLE STATION S MUTE TERMINALS TOGETHER 1...

Page 20: ...8 LINE BALANCE ASSEMBLY MODEL SF 1000LB FIG 6 KEY A Mounting Holes B Page Line Balance Adjustment L1 PARTY 5 L2 PARTY 4 L1 L2 PARTY 3 L1 L2 PARTY 2 L1 L2 PARTY 1 L1 L2 PAGE L1 L2 A B 290A4034 08...

Page 21: ...Detach template on next page for use during installation...

Page 22: ...3 25 MOUNTING HOLES 0 22 TYP 0 25 0 25 5 50 CUT OUT THIS AREA 290A4034 09B TEMPLATE FOR MODELS SF 1015P SF 1011P FEDERAL SIGNAL SELECTFONE INTERCOM PAGING SYSTEM...

Reviews: