Safety Messages

It is important to follow all instructions shipped with this product. This device is to be 

installed by trained personnel who are thoroughly familiar with the country’s electric 

codes and will follow these guidelines as well as local codes and ordinances, including 

any state or local noise-control ordinances.
Planning

•  If suitable warning equipment is not selected, the installation site for the Informer15 

Speaker is not selected properly, or the Informer15 Speaker is not installed properly, it 

may not produce the intended optimum audible warning. Follow Federal Emergency 

Management Agency (FEMA) recommendations. 

•  If Informer15 Speakers are not activated in a timely manner when an emergency 

condition exists, they cannot provide the intended audible warning. It is imperative 

that knowledgeable people, who are provided with the necessary information, be 

available at all times to authorize activation. 

•  When Informer15 Speakers are used out of doors, people indoors may not be able to 

hear the warning signals. Separate warning devices or procedures may be needed to 

effectively warn people indoors. 

•  The sound output of sirens is capable of causing permanent hearing damage. To 

prevent excessive exposure, carefully plan siren placement, post warnings, and 

restrict access to areas near sirens. Review and comply with any local or state noise 

control ordinances as well as OSHA noise exposure regulations and guidelines.

•  Activating the Informer15 Speaker may not result in people taking the desired actions 

if those to be warned are not properly trained about the meaning of warning sounds. 

Users should follow FEMA recommendations and instruct those to be warned of 

corrective actions to be taken.

After installation, service, or maintenance, test the system to confirm that it is operating 

properly. Test the system regularly to confirm that it will be operational in an emergency. 

Safety Messages to Installers

People’s lives depend on the safe installation of our products. It is important to follow 

all instructions shipped with this product. This device is to be installed by a trained 

electrician who is thoroughly familiar with the National Electrical Code and/or Canadian 

Electrical Code and will follow the NEC and/or CEC Guidelines as well as all local codes. 

This Informer15 Speaker should be considered a part of the warning system and not the 

entire warning system. 
The selection of the mounting location for this Informer15 Speaker, its controls and the 

routing of the wiring is to be accomplished under the Facilities Engineer and the Safety 

Engineer direction. Listed below are some other important safety instructions and 

precautions you should follow:
•  Electrocution or severe personal injury can occur when performing various 

installation and service functions such as making electrical connections, drilling 

holes, or lifting equipment. Therefore, only experienced electricians should install this 

Summary of Contents for Informer15 I-IP15

Page 1: ...ecifications Installation Operation and Service Manual 25500494 Rev C1 1220 Printed in U S A Copyright 2018 2020 Federal Signal Corporation Informer15 Speaker Model I IP15 Series C IP Enabled Indoor O...

Page 2: ...all 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness...

Page 3: ...cifications 10 Installation 13 Flat Surface Mounting 14 Opening the Housing 15 Wiring the Network and Power Connections 15 PoE model See Figure 2 15 24 Vdc model See Figure 3 16 Wiring to the Controll...

Page 4: ...s for the Controller Board 11 Table 4 Connectors and Jacks for the Amplifier Board 11 Table 5 Connectors and Jacks for the PoE Board PoE models only 12 Table 6 Connectors for the 24 Vdc Power Board 12...

Page 5: ...ens Review and comply with any local or state noise control ordinances as well as OSHA noise exposure regulations and guidelines Activating the Informer15 Speaker may not result in people taking the d...

Page 6: ...obstruct the sound output reducing the effectiveness of the horn Establish a procedure to check the signal system for proper activation and operation routinely Any maintenance to the unit MUST be perf...

Page 7: ...e power wiring or lightning rods and associated wires and at least six inches from other wire for example antenna wires doorbell wires wires from transformers to neon signs steam or hot water pipes an...

Page 8: ...cation has no network connectivity but where voice and tone alerts from locally activated inputs are required The Informer15 can be networked later and the activations can be brought into the Commande...

Page 9: ...or volume and noise level adjustments Speaker as a microphone for talkback feature Alerts can be sent to single devices groups or zones or all devices Integrated Modbus TCP industrial PLC interface fo...

Page 10: ...4 Vdc model 24 Vdc 1 0 A Serial Port Protocol FLASH programming and configuration Default 9600 bit s 8 data 1 stop no parity Configurable up to 115 200 bit s Open Collector Output Maximum 30 V or 100...

Page 11: ...lector Output 2 Output 1 24 Vdc JP8 Option1 Jumper Short pins 1 and 2 for Standalone Option JP9 Option2 Jumper Short pins 1 and 2 for Option JP11 Serial Port RJ25 6 conductor mod jack JP12 Controller...

Page 12: ...al Indications for the Controller Board D1 Power D2 Digital Input 1 active D3 Listen D4 Talk D5 Digital Input 2 active D7 Network connected D8 CPU running D9 Digital Input 3 active D11 Digital Input 4...

Page 13: ...allation crew safety foreman should perform the installation OBSTRUCTION HAZARD Property damage serious injury or death could occur if an accumulation of water snow dust etc resides in the speaker pro...

Page 14: ...ing surface See Figure 1 for mounting hole locations and dimensions DRILLING PRECAUTION Before drilling holes in any surface ensure that both sides of surface are clear of items that could be damaged...

Page 15: ...an eight pin Ethernet port for connecting to the network Ethernet wire runs must be less than 328 feet 100 meters from the nearest network switch Do not install in a conduit carrying high voltage The...

Page 16: ...ler Board 24 Vdc Power Input Board Amplifier Board To Amplifier Board To 24 Vdc Power Input Board JP1 JP2 JP3 M1 GND GND 24 Vdc 24 Vdc Wiring to the Controller Board To wire the Controller Board 1 Use...

Page 17: ...ations section of this manual When using this feature the open collector relay outputs turn on until one of the following occurs Until the programmed default timeout occurs Until the CANCEL or RESET c...

Page 18: ...ial system test establish a program for periodic testing of this device 3 Provide a copy of these instructions for the Safety Engineer system operator s and maintenance personnel Safety Message to Ope...

Page 19: ...als If a volume adjustment or other repair is required be sure to refer to the Safety Message before proceeding SOUND HAZARD Unauthorized repair servicing of the unit may result in degradation of perf...

Page 20: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400...

Reviews: