Preparing to Wire the Ex d Flameproof Models

SHOCK HAZARD: To avoid electrical shock, do not connect wires when power is applied. Failure to observe this 

warning may lead to serious injury or death.

Ex d units are supplied with a ten-position PCB mounted screw terminal block. This section has wiring instructions for 

the flameproof models G-SPK 70 V and 100 V.

The maximum wire gauge is 4.0 mm

2

  (12 AWG). The wire must be rated 85 °C or higher. Use only stranded cable to 

terminate the loudspeaker. The cross-sectional area of the primary earth (ground) must equal the cross-sectional area of 

the phase conductor.

Cable termination for these models should be in accordance with specifications that apply to the application. It is 

recommended that all cables and cores be fully identified. Use the appropriate cable gland for the application. Gland 

entry threads are M20-1.5 x 6" H.

Tools needed:

• 

1.5 mm A/F hexagon key

• 

No. 1 Phillips

®

 screwdriver

• 

Wire stripper

Figure 5  

Ex d in/out PCB connections (2.8 V/0.8 V

RMS

)

1

2

3

4

Wiring the Ex d Models

To wire the Ex d flameproof loudspeaker:

1. 

Unscrew the M3 hex set screw on the side of the housing one full turn.

2. 

Remove the cover from the housing by turning the cover counterclockwise. Three 120-degree spaced reliefs are 

provided for a 3/8" spanner wrench if needed. If the cover will not unscrew, back out the set screw a few additional 

turns.

3. 

Loosen the captive Phillips screw retaining the driver/printed circuit board (PCB).

4. 

Slide out the PCB until the terminals clear the housing. Strip the wire insulation 6.5 mm (0.25"). Maximum screw 

tightening torque is 0.5 Nm (4.5 in-lb)

5. 

The Model G-SPK has five selectable wattage tap settings on the high power setting and five selectable wattage 

tap settings on the low power setting. See Table 1 for options and terminal block wiring.

Each terminal block position has in/out connection points.

Summary of Contents for Global Series

Page 1: ...tightened After installation test the loudspeaker system to ensure that it is operating properly Keep the unit tightly closed when in operation After testing is complete provide a copy of this instruc...

Page 2: ...equipment is for use in Class I Zone 1 and Zone 21 hazardous classified locations It has been investigated with reference to risks to life and property and for conformity to the installation and use...

Page 3: ...apparatus must be securely attached to the mounting surface in accordance with the installation instructions Use installer supplied fasteners suitable for the mounting surface The mounting method and...

Page 4: ...ing the six 8 5 mm mounting holes Use installer supplied fasteners suitable for the surface to which the device will be mounted Figure 3 Front view of Ex de surface mount 2X 8 5 mm 103 2 mm 4 06 in 12...

Page 5: ...or reassembling the unit Painting and surface finishes other than those applied by Federal Signal Corporation are not permitted Cable termination should be in accordance with the specifications that...

Page 6: ...the application Gland entry threads are M20 1 5 x 6 H Tools needed 1 5 mm A F hexagon key No 1 Phillips screwdriver Wire stripper Figure 5 Ex d in out PCB connections 2 8 V 0 8 VRMS 1 2 3 4 Wiring th...

Page 7: ...y or death This section has wiring instructions for the increased safety models G SPK 70 V and 100 V Ex de units are supplied with a six pole spring tension clamp style terminal block The maximum wire...

Page 8: ...intaining the Loudspeaker SAFETY MESSAGES TO MAINTENANCE PERSONNEL Listed below are some important safety instructions and precautions you should follow Read and understand all instructions before ope...

Page 9: ...is as resistant to concentrated acids and alkalis as most metal products However if abnormal or unusual environment conditions occur due to plant damage or accident etc visual inspection of the louds...

Page 10: ...ervice A return authorization is required Contact your Authorized Distributor or Federal Signal Customer Support Defective products under warranty will be repaired or replaced at Federal Signal s disc...

Page 11: ...ion Box Spacer Kit G KIT EXTB Single Trunnion Kit G KIT ST Dual Trunnion Kit G KIT DT Adapter M20 Male to 1 2 Female NPT K231246A Adapter M20 Male to 3 4 Female NPT K231247 15 W Audible Acoustic Inser...

Page 12: ...ranslations available at signaling fedsig com Traducciones adicionales disponibles en signaling fedsig com Customer Support 1 800 344 4634 1 708 534 4756 iordersup fedsig com Technical Support 1 800 7...

Reviews: