Replacement Parts

Contact the factory for spare parts availability and part numbers. Typical spare parts are listed below. Due to certification, 

certain component parts are not available for field replacement. Units with this type of damage must be either replaced 

entirely or returned to Federal Signal for service. 

 Table 2  Replacement Part

Description

Part Number

70 V

RMS

, Loudspeaker Kit

 

(Includes PCBAs, Bracket, Driver, & Mounting Screws)

K859501405-070

100 V

RMS

 Loudspeaker Kit

 

(Includes PCBAs, Bracket, Driver, & Mounting Screws)

K859501405-100

 Table 3  

Accessories

Description 

Part Number

Indicator Ring/Legend Kit, Black

G-KIT-RP-BK

Indicator Ring/Legend Kit, Blue

G-KIT-RP-B

Indicator Ring/Legend Kit, Green

G-KIT-RP-G

Indicator Ring/Legend Kit, Magenta

G-KIT-RP-M

Indicator Ring/Legend Kit, Red

G-KIT-RP-R

Indicator Ring/Legend Kit, Yellow

G-KIT-RP-Y

E-Box Endcap with M20 Opening

K859500805-02

E-Box Endcap with M25 Opening

K859500805-01

E-Box Cover Assembly (Includes two terminal blocks, mounting plate, retention hardware)

K859501414

In-Line E-Box Coupler Kit

G-KIT-EC180

90-Degree E-Box Coupler Kit

G-KIT-EC90

Extension Box Spacer Kit

G-KIT-EXTB

Single Trunnion Kit

G-KIT-ST

Dual Trunnion Kit

G-KIT-DT

Adapter, M20 Male to 1/2" Female NPT

K231246A

Adapter, M20 Male to 3/4" Female NPT

K231247

15 W Audible Acoustic Insert

G-KIT-15WINSERT

 Table 4  

Choosing cable-entry devices for Equipment in Potentially Explosive Atmospheres

Models Ex

Atmospheres Cable Entry Devices (cable glands, stopping plugs, etc.)

G-SPK-XXX-D 

(Ex db surface mount)

Gas

Cable entry devices shall be equipment certified as flameproof. To maintain 

the ingress protection of the flameproof loludspeaker enclosure, we 

recommend the cable entry device be IP66 certified.

G-SPK-XXX-E 

(Ex db e surface mount)

Gas

For the flameproof loudspeaker enclosure, cable entry devices shall be 

equipment certified as flameproof. To maintain the ingress protection of the 

flameproof loudspeaker enclosure, we recommend the cable entry device be 

IP66 certified. For the increased safety terminal enclosures (terminal boxes), 

cable entry devices shall be equipment certified as increased safety and shall 

maintain an IP rating of IP54.

G-SPK-XXX-D 

(Ex db surface mount) 

G-SPK-XXX-E 

(Ex db e surface mount)

Dust

Cable entry devices for the terminal enclosures shall be equipment certified 

as dust protected. To maintain the ingress protection of the loudspeaker and 

terminal enclosures, the cable entry devices shall be IP6X certified.

Summary of Contents for Global Series

Page 1: ...tightened After installation test the loudspeaker system to ensure that it is operating properly Keep the unit tightly closed when in operation After testing is complete provide a copy of this instruc...

Page 2: ...equipment is for use in Class I Zone 1 and Zone 21 hazardous classified locations It has been investigated with reference to risks to life and property and for conformity to the installation and use...

Page 3: ...apparatus must be securely attached to the mounting surface in accordance with the installation instructions Use installer supplied fasteners suitable for the mounting surface The mounting method and...

Page 4: ...ing the six 8 5 mm mounting holes Use installer supplied fasteners suitable for the surface to which the device will be mounted Figure 3 Front view of Ex de surface mount 2X 8 5 mm 103 2 mm 4 06 in 12...

Page 5: ...or reassembling the unit Painting and surface finishes other than those applied by Federal Signal Corporation are not permitted Cable termination should be in accordance with the specifications that...

Page 6: ...the application Gland entry threads are M20 1 5 x 6 H Tools needed 1 5 mm A F hexagon key No 1 Phillips screwdriver Wire stripper Figure 5 Ex d in out PCB connections 2 8 V 0 8 VRMS 1 2 3 4 Wiring th...

Page 7: ...y or death This section has wiring instructions for the increased safety models G SPK 70 V and 100 V Ex de units are supplied with a six pole spring tension clamp style terminal block The maximum wire...

Page 8: ...intaining the Loudspeaker SAFETY MESSAGES TO MAINTENANCE PERSONNEL Listed below are some important safety instructions and precautions you should follow Read and understand all instructions before ope...

Page 9: ...is as resistant to concentrated acids and alkalis as most metal products However if abnormal or unusual environment conditions occur due to plant damage or accident etc visual inspection of the louds...

Page 10: ...ervice A return authorization is required Contact your Authorized Distributor or Federal Signal Customer Support Defective products under warranty will be repaired or replaced at Federal Signal s disc...

Page 11: ...ion Box Spacer Kit G KIT EXTB Single Trunnion Kit G KIT ST Dual Trunnion Kit G KIT DT Adapter M20 Male to 1 2 Female NPT K231246A Adapter M20 Male to 3 4 Female NPT K231247 15 W Audible Acoustic Inser...

Page 12: ...ranslations available at signaling fedsig com Traducciones adicionales disponibles en signaling fedsig com Customer Support 1 800 344 4634 1 708 534 4756 iordersup fedsig com Technical Support 1 800 7...

Reviews: