Install the siren electrical system in compliance with local electrical 
codes and NEC recommendations. Federal Signal also recommends 
that all user-installed conduit connections enter from bottom of all 
enclosures. 

 

Solidly connect siren units and control units to an earth ground. If the 
siren is installed on a building, ground the system to a metallic object 
known to be grounded. For pole mounted installations, drive a metal rod 
or bar at least eight feet into the ground, as close as practical to the 
base of the pole. For maximum protection, use a separate, continuous 
6 AWG or larger wire from the siren frame to ground and from the 
enclosure of each siren unit to ground. 

Connecting the Siren 

The 2001-AC parts list and wiring diagrams are shown in Figure 4 Motor Starter 
Enclosure Parts List, Figure 5 Motor Starter Wiring, and Figure 6 Typical Wiring 
Diagram.  

 

Typical connections between the siren and control unit are accomplished using 
user supplied wires. Two 2 AWG wires provide operating power to the siren 
motor. If required, an additional 12 AWG wire provides operating power to the 
rotator motor.  

 

Route the interconnecting cable through conduit between the siren and the Motor 
Starter Enclosure. There is a three position terminal block (shown in Figure 7 
Terminal Block in Rotator Housing) located in the rotator housing of the siren 
that accepts stripped wire.  

 

In the Motor Starter Enclosure, the DC GROUND terminal block TB1, accepts 
user supplied 5/16 inch ring terminals and the relays accept user supplied 

¼

 inch 

ring terminals. The Motor Starter coils accept user supplied 

¼

 inch spade 

terminals. These points provide convenient locations for making all electrical 
connections. 

Connect the siren to the Motor Starters, as follows: 

1.  After drilling or punching an appropriate sized hole in the enclosure, install a 1 

inch user supplied electrical conduit fitting in the bottom of the enclosure and in 
the bottom of the siren rotator housing. 

Summary of Contents for 2001-AC

Page 1: ...2001 AC DC Motor Starters and Transformer Rectifier Plus Options 2001HR Holding Relay Radio Activation Installation and Operation Manual 255252 Rev L4 0616 Printed in U S A...

Page 2: ...2001 AC Copyright 2016 Federal Signal Corporation...

Page 3: ...to the product or labor charges for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the...

Page 4: ...2001 AC Website http www alertnotification net...

Page 5: ...01HR 5 Battery Backup 5 Specifications 6 Installation Instructions 7 Location and Installation 7 Locating the 2001 AC 7 Installation Requirements 9 Installation 9 Pole Mounting 9 Flat Surface Mount 10...

Page 6: ...gure 3 Typical Siren Installation Drawing 8 Figure 4 Motor Starter Enclosure Parts List 11 Figure 5 Motor Starter Wiring Diagram with HR Option 12 Figure 6 Typical Wiring Diagram 13 Figure 7 Terminal...

Page 7: ...agement Agency for assistance with planning an outdoor warning system The Outdoor Warning Guide CPG 1 17 Civil Preparedness Principles of Warning CPG 1 14 FEMA REP 1 Appendix 3 Nuclear Plant Guideline...

Page 8: ...rocution or severe personal injury can occur when performing various installation and service functions such as making electrical connections drilling holes or lifting equipment Therefore only experie...

Page 9: ...ead and thoroughly understand all safety notices in this manual and all operations related items in all instruction manuals shipped with equipment Thoroughly discuss all contingency plans with those r...

Page 10: ...as a siren Figure 1 2001 AC FC control purchased separately Describing the Motor Starter and the Transformer Rectifier The 2001 AC consists of two enclosures that you can separately mount for ease of...

Page 11: ...FC Controllers are capable of both radio and local push button control These controllers are available in UHF and VHF bands Landline cellular satellite and IP options are available contact your local...

Page 12: ...5 VAC at 10 Amps Operating Current 100 Amps Nom Fusing 200 Amps fast Contactors Contact Rating 200 A at 48 VDC Coil 48 VDC 110 ohms General Continuous Full Output Signaling Time 30 minutes Operating T...

Page 13: ...eral Signal recommends that you install the 2001 AC within 50 feet of the siren or other equipment being activated If it is necessary to make a longer cable run Federal Signal recommends increasing th...

Page 14: ...8 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 3 Typical Siren Installation Drawing...

Page 15: ...rminals 1 2 AWG inch ring terminal 1 12 AWG inch ring terminal 3 10 AWG wire nuts Approximately 50 feet of 1 inch conduit inch conduit length depends on install Ground wiring rod and or clamps Install...

Page 16: ...accordance with local and national electric codes on the pole beneath or opposite the Control Unit Transformer Rectifier assembly in line with the primary AC service Flat Surface Mount To attach the...

Page 17: ...2001 AC 11 Installation Instructions Figure 4 Motor Starter Enclosure Parts List...

Page 18: ...12 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 5 Motor Starter Wiring Diagram with HR Option...

Page 19: ...2001 AC 13 Installation Instructions Figure 6 Typical Wiring Diagram...

Page 20: ...Motor Starter Wiring and Figure 6 Typical Wiring Diagram Typical connections between the siren and control unit are accomplished using user supplied wires Two 2 AWG wires provide operating power to th...

Page 21: ...al Block in Rotator Housing 5 Connect a 2 AWG wire 48 VDC from the terminal block in the rotator housing terminal 2 to the rotor control relay K2 2 user supplied inch ring terminal required 6 Connect...

Page 22: ...Transformer Rectifier Enclosure and the Motor Starter Enclosure 5 Route two user supplied wires through the conduit that was just installed between the Transformer Rectifier and Motor Starter Use 3 A...

Page 23: ...motor and the rotator motor are activated When the connection to ground is removed power to the siren motor is removed and the rotator motor remains on for fifteen 15 seconds to allow a single contac...

Page 24: ...est the 2001 AC for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public c...

Page 25: ...could occur when working on this equipment Service should only be performed by personnel familiar with 240 VAC power and only after reading this manual The following checklist should be completed if...

Page 26: ...20 2001 AC Service and Maintenance MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 9 Transformer...

Page 27: ...6 I Installation Instructions 7 Installation Requirements 9 Introduction to the 2001 AC 4 L Locating the 2001 AC 7 M Maintenance 18 Motor Starter 4 P Pole Mounting 9 Pre Operation Checkout 17 Preventi...

Page 28: ...2645 Federal Signal Drive University Park IL 60484 3167 Phone 708 534 3400 Website http www alertnotification net...

Reviews: