14
Installation
Models 2-120 and 2-240
Federal Signal www.fedsig.com
Figure 3 Typical Model 2 Pole-Mounted Installation
291A124A1
GROUND LINE
TWO 8 FOOT GROUND RODS
6 Ga. GROUND WIRE
WEATHER PROOF CABT.
TO HOUSE SIREN
FUSED DISCONNECT
FC UNIT
RIGID CONDUIT
*
CUSTOMER SUPPLIED
*
*
*
*
*
CONTROL WIRING
SWITCH
MOTOR STARTER
ANTENNA
TO BE NO. 4 COPPER OR
GALVONIZED IRON, WITH
TWO CONTINUOUS NO.6
COPPER GROUND WIRES AND
CLAMPS, OR EQUIVALENT.
Flat Surface Mount
Flat surface mount installation is practical when the installation site is on a flat roofed
building. A weight distribution mat is often required to safely distribute the siren’s weight
on the roof. A Structural Engineer is required to specify the appropriate mounting method
to safely mount the siren on a roof.
Post high sound level warning signs at all roof entry points and be sure that the siren is
not blocked by parapets or other obstructions in the siren’s sound path.