SPECIFICATIONS: PORT-A-CART
™
Power Requirement: 120 volts, 60 Hz,
1
Phase,
17
amps,
1612
watts
Weight:
400
lbs.
(180
kg)
Dimensions:
48.1”L x 29.5” W x 33.5” H
(1222 x 749 x 851 mm)
Filter Area:
190 Sq. Ft. (17.7 Sq. m)
Backflush Air Pressure:
80-120PSI(1/4” shop hose
or
larger)
5.5-8.3
Pascals
(6mm
shop
hose
or
larger)
Arm:
6.5’ L, 8” diameter
externally
supported
with
360
rotation
(2m
x
200mm)
Pick-Up Velocity:
2000 FPM (10 MPS)
Duct Velocity:
2900 FPM (15 MPS)
Capture Zone:
12” to 18”
(300
to
450mm)
Filtered Air:
1000 CFM (1700 M3H)
SYSTEM DESIGN
SYSTEM DESIGN AND LAYOUT
WARNING!
The Port-A-Cart is NOT designed to collect
wet or oily particulate and should not be in-
stalled in applications collecting coolants,
grease, processing fluids or other types of
liquid aerosols. Contact the Trion sales de-
partment for special units for these type in-
stallations at 800-884-0002.
The Port-A-Cart Cartridge Air Cleaner is de-
signed to pick-up and collect dry solid particu-
late such as weld fumes and industrial dust.
Clean air is then discharged back into the
work space. The unit is equipped with cast-
ers, a source capture arm, a filtration compart-
ment, and a blower compartment. Simply roll
the unit to a level location near the source of
pollutants, adjust the arm, and place the cast-
ers in the locked position. Then connect the
electrical power and the unit is ready for op-
eration.
In operation, the pick-up arm delivers the con-
taminated air to the cartridge filter for collec-
tion. A Minihelic gauge monitors the pressure
across the cartridge filter and indicates when
cleaning should take place.
INSTALLATION
1.
UNPACK AND INSPECT
Upon receipt, all shipping containers and their
contents should be examined for damage. Any
damage occurring in shipment must be imme-
diately reported to the carrier, an inspection
report completed and a claim filed with the
carrier at the receiving point.
The Port-A-Cart cabinet is shipped assem-
bled. Please check to ensure all components
are included:
•
Painted steel cabinet with integral car-
tridge filter, casters, and power cord
•
Minihelic gauge
•
Drop-Out tray
•
Source capture arm, hood, and mounting
hardware (shipped loose)
•
Impregnated carbon filter (odor control)
2.
INSTALLING SOURCE CAPTURE ARM
To simplify packaging and reduce the possibil-
ity of shipping damage, the source capture
arm is shipped separately. The necessary
mounting hardware is included with the arm.
Using washers and bolts provided, secure the
arm to the cabinet. The mounting holes are
pre-drilled. The tension is adjustable at each
arm elbow (five places). The hood tension
adjustment is located outside the hood.
Summary of Contents for Trion PORT-A-CART
Page 8: ...8 Figure 1 Wiring Diagram...
Page 9: ...9 Figure 2 Outline Diagram...
Page 11: ...11 Figure 3 Parts List Diagram...