Name

Function

Name

Function

(1) Display unit

(2) Power switch

Used to turn the power ON or OFF.

(3) Memory card 

slot

(4) Memory card 

ejection button

To remove the memory card from the slot,  
press this button.

(5) Connector to

parameter 
loader

(6)

Allows the Real time trend screen, Bar Graph 
Display screen, Analog Meter Display screen, 
Digital Display screen, Totalized Value Display 
screen, Historical trend screen and other various 
Parameter Set screens to be displayed.

When changing parameters by using a loader, 
connect the exclusive cable (optional cable: Type; 
PHZP1801 or USB cable [USB (A) male – USB 
(mini B) male] to the connector.

Memory card

We recommend to use our separately-sold 
compact flash which we ensure performance. 

S1 REC key

S2 DISP key

• Used to start or stop recording.

Pressing once starts recording, and pressing once 
again stops recording.

• U

sed to switch displayed contents.  Every time it is 

pressed, the display is switched in the following 
order: (1)    (2)    (3)    (4)    (5)    (6)    (7) and back 
to (1).

(1) Real time trend display
(2) Key guidance display
(3) Bar graph/analog meter display
(4) Digital display
(5) Totalizing data display
(6) Event summary display
(7) Ethernet log display

• Used to switch the parameter setting screen to 

the data display screen.

S3 SEL key

• Used to switch from the data display screen to the 

parameter setting screen.

• Pressing the key on the parameter setting screen 

switches to the screen one step up.

  Note, however, that pressing the key on the menu 

screen does not change screens.

S4 Cursor key

(1) Used for selection on the setting screen or 

registration of the set data.

(2) If the key is pressed while the scales are 

displayed on the real time trend display screen, 

 

historical trend display screen (*1), or recorded 
data display screen, the channels for which 

 

scales are to be displayed can be switched.

 

(Scale of ch1      scale of ch2      …..      scale 
of ch9      scale of ch1      scale of ch2…..)

S5 ENT key

(1) Used to select setting items.
(2) Used to increase or decrease numerical values.
(3) Pressing the      key on the real time trend 

displays the historical trend screen (*1). 

 

At this time, the window can be scrolled using 
the cursor key.

(4) Pressing the    or the    key on the real time trend 

display, bar graph/analog meter display, digital 
display, or totalized value display screen 
switches group screens as follows.

 

key: Group 1    2    3    4    5    6    7    8    1   ...

 

key: Group ...   1    8    7    6    5    4    3    2    1    

*1:  The screen in the past of the data 
 

currently recorded

*1:  The screen in the past of the data 
 

currently recorded

Used for inserting the memory card. 
Insert the card straight into the slot as shown in 
upper right figure. 
Be careful not to forcibly press the card if it is 
inserted obliquely.  Otherwise the pin on the PHW 
may be damaged.

Caution

1.  Do not remove the memory card during recording.  Refer to the 

another Manual in the CD-ROM “Removing memory card 
(compact flash)” for the removal of the memory card while 
recording is in progress.

2.  After inserting the memory card into the slot, don’t remove the 

card until the recorder can acknowledge it.

3.  Be careful with static electricity when removing the memory card.

Caution

(1)

(2)

(3)

(6) (4) (5)

S5

S4

S3

S2

S1

Operation parts and their functions

3  Usage (Read before using)

Summary of Contents for PHW

Page 1: ...will not be bear any responsibility for a trouble caused by such a modification This instruction manual should be kept by the person who is actually using the unit After reading the manual be sure to...

Page 2: ...and breakdown of the instru ment Never turn on the power before all the mounting and wiring work are finished to prevent electric shock malfunction or failure of the instrument Never use this instrume...

Page 3: ...tween the unit and panel 2 3 Cautions for wiring connection Only authorized workers should perform wiring Improper wiring may cause fire failure or electric shock Be sure to ground the instrument Othe...

Page 4: ...ck or fire may result When cleaning the main unit wipe with a dry cloth Dispose the instrument as an industrial waste This product contains a CR Coin Lithium Battery which contains Perchlorate Materia...

Page 5: ...l the unit becomes thermally stable wait for 60 minutes or more after turning the power on before making measurements etc Terminal connection diagram Displays during abnormalities Stopping and startin...

Page 6: ...16 1 17 2 18 3 19 4 20 5 21 6 7 8 9 22 10 23 11 24 12 25 13 26 14 27 15 70 55 71 56 72 57 73 58 74 59 75 60 61 62 63 76 64 77 65 78 66 79 67 80 68 81 69 option option option R MODULE R MODULE R MODUL...

Page 7: ...screens S4 Cursor key 1 Used for selection on the setting screen or registration of the set data 2 If the key is pressed while the scales are displayed on the real time trend display screen historica...

Page 8: ...firm the selection Repeat until all the characters are input then move the cursor to Register and press the key There are two types of parameters In the case of 4 select the parameter using the key an...

Page 9: ...ing mode With Record Message Blank Timing None Display Name Display group 1 to 8 Trend Direction Vertical Display Divided to 10 14 colors Display color OFF ON Bar graph Analog meter Trend scale displa...

Page 10: ...TP IP address 0 0 0 0 Triigger timing None Text 2 Blank PV value affixation OFF Receiver s address No None CF manager 0000 0000 to 9999 No password at 0000 Parameter Setting 0000 Up to 32 characters T...

Page 11: ...4 bytes Measurement data 2 bytes number of input points From the above if the number of input point is 9ch 4 2 9 22 bytes Specification Power voltage Power consumption VA Input measurement range Recor...

Page 12: ...guage Japanese English Alarm relay output DI input Without Relay 10 points Relay 20 points Transistor open collector 16 points Relay 10 points Transistor open collector 16 points Relay 20 points Trans...

Reviews: