FE PHW Quick Reference Download Page 5

– 5 –

For Proper Usage

<Reference Item>

<Details>

When the display does not make sense.

6

Turn Power On

Wiring

2

Usage (Read before using)

3

Display and Operation Methods

4

List of parameters

5

Operation

Installation

1

Model Designation Confirmation

•  Please confirm that the model 

delivered matches your order.

•  Dimensions
•  Panel cutout
•  How to install on the panel

•  Operation parts and their 

functions

•  How to handle the memory 

card

•  How to change the data 

display screen

•  How to change the parameter 

setting screen

•  Setting of parameters

Since about 60 minutes is needed until the unit becomes 
thermally stable, wait for 60 minutes or more after turning the 
power on before making measurements, etc.

•  Terminal connection diagram

•  Displays during abnormalities.

•  Stopping and starting the 

recording

Dimensions/Panel Cutout 

Cautions on wiring

•  Use  crimped  terminals  matched  to  the  screw  size.  

Tightening torque should be about 0.2 N·m.

•  Do not connect anything to terminals not used.

AC power source

Protective grounding

Power ON

Double insulation

Power OFF

Electric shock hazard

1  Installation

(unit : mm)

Dimensions

Panel cutout

Note1)  If other instruments are placed under the recorder unit, 
 

provide a space of 100 mm or more from the instrument or floor.

PUSH

300

280

220.5

175

26

300

Mounting fixture

281

+2

0

320 MIN

281

+2

0

360 MIN

Panel

t

2 ≤ t ≤ 26

Summary of Contents for PHW

Page 1: ...will not be bear any responsibility for a trouble caused by such a modification This instruction manual should be kept by the person who is actually using the unit After reading the manual be sure to...

Page 2: ...and breakdown of the instru ment Never turn on the power before all the mounting and wiring work are finished to prevent electric shock malfunction or failure of the instrument Never use this instrume...

Page 3: ...tween the unit and panel 2 3 Cautions for wiring connection Only authorized workers should perform wiring Improper wiring may cause fire failure or electric shock Be sure to ground the instrument Othe...

Page 4: ...ck or fire may result When cleaning the main unit wipe with a dry cloth Dispose the instrument as an industrial waste This product contains a CR Coin Lithium Battery which contains Perchlorate Materia...

Page 5: ...l the unit becomes thermally stable wait for 60 minutes or more after turning the power on before making measurements etc Terminal connection diagram Displays during abnormalities Stopping and startin...

Page 6: ...16 1 17 2 18 3 19 4 20 5 21 6 7 8 9 22 10 23 11 24 12 25 13 26 14 27 15 70 55 71 56 72 57 73 58 74 59 75 60 61 62 63 76 64 77 65 78 66 79 67 80 68 81 69 option option option R MODULE R MODULE R MODUL...

Page 7: ...screens S4 Cursor key 1 Used for selection on the setting screen or registration of the set data 2 If the key is pressed while the scales are displayed on the real time trend display screen historica...

Page 8: ...firm the selection Repeat until all the characters are input then move the cursor to Register and press the key There are two types of parameters In the case of 4 select the parameter using the key an...

Page 9: ...ing mode With Record Message Blank Timing None Display Name Display group 1 to 8 Trend Direction Vertical Display Divided to 10 14 colors Display color OFF ON Bar graph Analog meter Trend scale displa...

Page 10: ...TP IP address 0 0 0 0 Triigger timing None Text 2 Blank PV value affixation OFF Receiver s address No None CF manager 0000 0000 to 9999 No password at 0000 Parameter Setting 0000 Up to 32 characters T...

Page 11: ...4 bytes Measurement data 2 bytes number of input points From the above if the number of input point is 9ch 4 2 9 22 bytes Specification Power voltage Power consumption VA Input measurement range Recor...

Page 12: ...guage Japanese English Alarm relay output DI input Without Relay 10 points Relay 20 points Transistor open collector 16 points Relay 10 points Transistor open collector 16 points Relay 20 points Trans...

Reviews: