Command sets for controlling the monitors with serial numbers starting w/
12XXXXXXXX (10 digits) and above:
Commands
Length CMD Index Wall ID Set ID Data
Wall
Column ID Check Sum
Power On
0x08
0x12
0x9C
0x00
0x00
0x01
0x01
0x48
Power Off
0x08
0x12
0x9C
0x00
0x00
0x00
0x01
0x49
HDMI 1
0x08
0x12
0x8E
0x00
0x00
0x00
0x01
0x57
HDMI 2
0x08
0x12
0x8E
0x00
0x00
0x01
0x01
0x56
DVI
0x08
0x12
0x8E
0x00
0x00
0x02
0x01
0x55
VGA
0x08
0x12
0x8E
0x00
0x00
0x03
0x01
0x54
S-Video
0x08
0x12
0x8E
0x00
0x00
0x04
0x01
0x53
Composite
0x08
0x12
0x8E
0x00
0x00
0x05
0x01
0x52
Auto
0x08
0x12
0x7E
0x00
0x00
0x00
0x01
0x67
Full
Screen
0x08
0x12
0x7E
0x00
0x00
0x01
0x01
0x66
16:9
0x08
0x12
0x7E
0x00
0x00
0x02
0x01
0x65
4:3
0x08
0x12
0x7E
0x00
0x00
0x03
0x01
0x64
1:1
0x08
0x12
0x7E
0x00
0x00
0x04
0x01
0x63
The RS-485 connector carries information between the Infrared received and the LCD
controller board. Any connections to the RS-485 bus must be tolerant to the existing control
signals. Devices connected to the RS-485 Bus should not send traffic that interferes with the
existing RS-485 messages.
*Note: The formula for checksum:
0xFF - ( CMD + Index + Wall ID + Set ID + Data + Wall Column ID - 1)