FCS S30 Surveyor User Manual Download Page 8

 

 

8

 
From the information listed above, it should be clear that leak 
sound travels well in metallic pipe and not very well in plastic 
pipe.  Once leak sound is detected, treat the leak as a "known 
leak" and listen at several access points to determine the 
approximate location and where to place the transducers for 
pinpointing with the correlator.  

 
 

6.2  TRANSDUCER CONTACTING METHODS  

 

The  S30  provides  two  different  methods  of  contacting  these 
access points.  
 

 

1. 

Magnet  -  to  attach  the  transducer  to  iron  or  steel 

access points (e.g., valve operating nut).  

 
2. 

Extendable Probe Rod - The rod can be made up for 
17",  33"  or  49"  length  to  reach  valves  or  curb  stops 
below  which  may  be  buried  or  under  water.    Simply 
attach the magnet to the Wave Guide, followed by the 
rods  to  make  up  the  desired  length.  See  diagram 
below.  

 

 
 
 

 

Summary of Contents for S30 Surveyor

Page 1: ...S30 Surveyor S30 Surveyor User Manual Fluid Conservation Systems Inc 502 TechneCenter Drive Suite B Milford Ohio 45150 Phone 800 531 5465 www fluidconservation com...

Page 2: ...ON PAGE 1 0 INTRODUCTION 3 2 0 SYSTEM COMPONENTS 3 3 0 CONNECTIONS CONTROLS INDICATIONS 4 5 4 0 LEAK SOUND WAVES 6 5 0 TRANSDUCERS 6 7 6 0 LEAK DETECTION 7 10 7 0 LEAK PINPOINTING 10 8 0 BATTERY REPLA...

Page 3: ...ate sound intensity measurements Adjustable Meter Control To ensure accurate readings in a variety of environments Lightweight compact rugged and weather resistant to withstand daily field use The S30...

Page 4: ...nsducer The connector assembly has been mounted to the transducer and packed with a special purpose silicone grease to waterproof the sensor and to prevent corrosion of the terminals Note WHENEVER THE...

Page 5: ...n of a leak 3 7 METER GAIN Allows the operator to adjust the sensitivity of the meter when the noise level is too high or too low for the present setting Turn the meter clockwise one click if the mete...

Page 6: ...uid and through the walls of the pipe Therefore in order to detect leak sound a device must be able to detect the leak sound vibrations in the pipe wall or alternatively on pipe fittings valves hydran...

Page 7: ...for detecting unknown leaks a leak survey must be conducted A leak survey is the process of monitoring the distribution system for the sound of leaks 6 1 ACCESS POINTS AND SURVEY FREQUENCY The typica...

Page 8: ...ansducers for pinpointing with the correlator 6 2 TRANSDUCER CONTACTING METHODS The S30 provides two different methods of contacting these access points 1 Magnet to attach the transducer to iron or st...

Page 9: ...ine two things 1 Do you hear leak sound 2 What is the intensity of that leak sound If leak sound is monitored note the location and relative signal level for reference When this has been completed the...

Page 10: ...ze this method the operator must already know that there is a leak in the vicinity and he must know where the water main is located 7 1 SET UP To properly use the S30 for pinpointing the ground microp...

Page 11: ...by experience 8 0 BATTERY REPLACEMENT To replace the batteries remove the two screws from the back plate To access the batteries slide the top Black cover on the S30 back away from the removed screws...

Page 12: ...mage which occurs in shipment or failure which results from alteration accident misuse abuse neglect or improper maintenance This warranty is void if the serial number has been altered or removed from...