FCS S30 Surveyor User Manual Download Page 4

 

 

4

3.0  CONNECTIONS, CONTROLS AND INDICATIONS 
 

Rear Panel 

 

 

 

Diagram I – Rear Panel 

 

3.1 

SENSOR  CONNECTOR:    Accepts  the  male  LEMO  plug  from 

the AX80 transducer. 

 
3.2 

TRANSDUCER  (SENSOR)  CABLE:    The  AX80  transducer  is 

provided  with  a  rugged  10  ft.  cable.    This  cable  is  mounted  to 
the  transducer  by  means  of  a  screw-on  type  connector.    This 
allows  for  replacement  of  the  cable  in  case  of  damage  to  a 
connector or the cable itself.  Under typical day-to-day use, the 
cable should remain attached to the transducer.  The connector 
assembly has been mounted to the transducer and packed with 
a special purpose silicone grease to waterproof the sensor and 
to prevent corrosion of the terminals.    

Note: 

WHENEVER

 

THE

 

CONNECTOR/CABLE

 

ASSEMBLY

 

IS

 

DISCONNECTED

 

FROM

 

THE

 

TRANSDUCER,

 

REPACK

 

THE

 

CONNECTOR

  

WITH

 

A

 

DAB

 

OF

 

G.E.

 

#661

 

SILICONE

 

GREASE.

  

DO

 

NOT

 

USE

 

ANY

 

OTHER

 

SUBSTANCE.

 

 

3.3 

BACKLIGHT SWITCH:  Controls the backlight mode of the unit.  
To  enable  the  meter  backlight,  press  the  switch  into  the  “ON” 
position.  To turn the backlight off, select the “OFF” position. 

 
3.4 

HEADPHONE/CABLE JACK: Used to provide the audio output 
to the operator.  For survey, insert the headphone plug into the 
jack to monitor the output.  

 
 

 

Summary of Contents for S30 Surveyor

Page 1: ...S30 Surveyor S30 Surveyor User Manual Fluid Conservation Systems Inc 502 TechneCenter Drive Suite B Milford Ohio 45150 Phone 800 531 5465 www fluidconservation com...

Page 2: ...ON PAGE 1 0 INTRODUCTION 3 2 0 SYSTEM COMPONENTS 3 3 0 CONNECTIONS CONTROLS INDICATIONS 4 5 4 0 LEAK SOUND WAVES 6 5 0 TRANSDUCERS 6 7 6 0 LEAK DETECTION 7 10 7 0 LEAK PINPOINTING 10 8 0 BATTERY REPLA...

Page 3: ...ate sound intensity measurements Adjustable Meter Control To ensure accurate readings in a variety of environments Lightweight compact rugged and weather resistant to withstand daily field use The S30...

Page 4: ...nsducer The connector assembly has been mounted to the transducer and packed with a special purpose silicone grease to waterproof the sensor and to prevent corrosion of the terminals Note WHENEVER THE...

Page 5: ...n of a leak 3 7 METER GAIN Allows the operator to adjust the sensitivity of the meter when the noise level is too high or too low for the present setting Turn the meter clockwise one click if the mete...

Page 6: ...uid and through the walls of the pipe Therefore in order to detect leak sound a device must be able to detect the leak sound vibrations in the pipe wall or alternatively on pipe fittings valves hydran...

Page 7: ...for detecting unknown leaks a leak survey must be conducted A leak survey is the process of monitoring the distribution system for the sound of leaks 6 1 ACCESS POINTS AND SURVEY FREQUENCY The typica...

Page 8: ...ansducers for pinpointing with the correlator 6 2 TRANSDUCER CONTACTING METHODS The S30 provides two different methods of contacting these access points 1 Magnet to attach the transducer to iron or st...

Page 9: ...ine two things 1 Do you hear leak sound 2 What is the intensity of that leak sound If leak sound is monitored note the location and relative signal level for reference When this has been completed the...

Page 10: ...ze this method the operator must already know that there is a leak in the vicinity and he must know where the water main is located 7 1 SET UP To properly use the S30 for pinpointing the ground microp...

Page 11: ...by experience 8 0 BATTERY REPLACEMENT To replace the batteries remove the two screws from the back plate To access the batteries slide the top Black cover on the S30 back away from the removed screws...

Page 12: ...mage which occurs in shipment or failure which results from alteration accident misuse abuse neglect or improper maintenance This warranty is void if the serial number has been altered or removed from...

Reviews: