12
ST100 Series Profibus PA
Pressure Analog Input (AI) Block
The instruments equipped with a pressure sensor will make use of the Pressure AI block. This block gets its input from the Pressure transducer Block.
REL. INDEX
PARAMETER
SLOT
INDEX
DATA TYPE (LENGTH) STORE
SIZE
READ/WRITE
1
ST_REV
3
17
UNSIGNED16
N
2
R
2
TAG_DESC
3
18
OCTETSTRING
S
32
RW
3
STRATEGY
3
19
UNSIGNED16
S
2
RW
4
ALERT_KEY
3
20
UNSIGNED 8
S
1
RW
5
TARGET_MODE
3
21
UNSIGNED 8
S
1
RW
6
MODE_BLK
3
22
DS-37
S
3
R
7
ALARM_SUM
3
23
DS-42
D
8
R
8
BATCH
3
24
DS-67
S
10
RW
10
OUT (PRESS.)
3
26
DS-33
D
5
R
11
PV_SCALE
3
27
FLOAT
S
8
R/W
12
OUT_SCALE
3
28
DS36
S
11
R/W
13
LIN_TYPE
3
29
UNSIGNED 8
S
1
R/W
14
CHANNEL
3
30
UNSIGNED16
S
2
R/W
16
PV_FTIME
3
32
FLOAT
S
4
R/W
17
FSAFE_TYPE
3
33
UNSIGNED 8
S
1
R/W
18
FSAFE_VALUE
3
34
FLOAT
S
4
R/W
19
ALARM_HYS
3
35
FLOAT
S
4
R/W
21
HI_HI_LIM
3
37
FLOAT
S
4
R/W
23
HI_LIM
3
39
FLOAT
S
4
R/W
25
LO_LIM
3
41
FLOAT
S
4
R/W
27
LO_LO_LIM
3
43
FLOAT
S
4
R/W
30
HI_HI_ALM
3
46
DS-39
D
16
R
31
HI_ALM
3
47
DS-39
D
16
R
32
LO_ALM
3
48
DS-39
D
16
R
33
LO_LO_ALM
3
49
DS-39
D
16
R
34
SIMULATE
3
50
DS50
S
6
R/W
35
OUT_UNIT_TEXT
3
51
OCTETSTRING
S
16
R/W
Fluid Components International LLC
Summary of Contents for ST100 series
Page 24: ...ST100 Series Profibus PA 20 Fluid Components International LLC INTENTIONALLY LEFT BLANK...
Page 32: ...ST100 Series Profibus PA 28 Fluid Components International LLC INTENTIONALLY LEFT BLANK...
Page 34: ...ST100 Series Profibus PA 30 Fluid Components International LLC NOTES...
Page 35: ...ST100 Series Profibus PA Fluid Components International LLC 31 INTENTIONALLY LEFT BLANK...