FLAME฀TUBE฀LENGTH

Flame฀tube฀length฀must฀be฀selected฀based฀on฀the฀specifications฀supplied฀by฀boiler฀manufacturer฀and,฀in฀any฀case,฀it
must฀be฀greater฀than฀the฀thickness฀of฀the฀boiler฀door฀included฀its฀insulation.
In฀case฀of฀boilers฀with฀flame฀inversion฀or฀front฀flue฀combustion฀chambers,฀it฀is฀necessary฀to฀insulate฀the฀area฀between
the฀flame฀tube฀and฀front฀door฀with฀refractory฀material.฀This฀protection฀material฀must฀not฀impede฀flame฀tube฀
extraction.

**฀For฀different฀flame฀lengths,฀please฀contact฀our฀Technical-Sales฀Department.

MODEL

TC

TL **

FGP฀50/M฀EVO

mm

250

335

BOILER฀PLATE

* Suggested฀dimension฀of฀connection฀between฀burner
and฀generator.

Fig. 4 

Boiler฀plate

MODEL

FGP฀50/M฀EVO

mm

M

N min

N max

L

฀min

M10

205

226

160

L฀*

L

฀max

160

1

8

0

LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀

OR฀MODULATING