background image

Wiring the Omni-EXP8

Connect zone wiring as shown in the diagrams below.

The following diagram shows the 8 zones (L1-L8), available on the Omni-EXP8, wired as end-of-line:

P2

P3

OMNI-EXP 8

HARDWIRE ZONE EXPANDER

L1 L2

L3 L4

L5 L6

L7 L8

OMNI-EXP8-002-V0

Each zone may be wired in any of the three configurations shown in the following diagram:

2.2k

2.2k

2.2k

2.2k

2.2k

2.2k

TAMPER

CONTACTS

TYPICAL DOUBLE

BALANCED ZONES

TYPICAL CONNECTION

FOR ZONE DOUBLING

7.5k

Z2

3.3k

Z1

STANDARD EOL

2.2k

OMNI-EXP8-003-V0

Note: If this zone expander is being used in EOL CE installations, the following wiring diagram applies using 7.5k

resistors:

P2

P3

OMNI-EXP 8

HARDWIRE ZONE EXPANDER

L1

L2

L3

L4

L5

L6

L7

L8

12

OMNI-EXP8-004-V0

Specifications:

Dimensions: 1.9” H x 3.5” W (48.3mm x 89mm)

Temperature Range: 0

°

 C to 50

°

 C

Current Draw: 12mA

- 2 -