Miscellaneous Commands 

(cont)

TURN CHIME ON/OFF

Chime is an optional feature that causes the keypad to chime when selected
doors are opened while the burglary protection is off or disarmed.

Only your installer can program a zone for the Chime feature, but once
programmed, you can turn Chime on or off to meet your daily needs.
To turn Chime on or off: Press  [#], then [6].

SET AUTO ON TIME

Set Auto On Time lets you set the time your system will automatically turn on.

To activate Set Auto On Time: Press [#], then [5]  [hour] [minute].

The readout keypad will prompt you for the required entries.

DOOR STRIKE

To activate door strikes:

Press [#], then [9], then [Door #] 

(Note  that  the  installer  may  have
assigned User 13 as the only user that
can perform the door strike function).

where the door number is as follows:

1 ________________________ 

3 __________________________

2 ________________________ 

4 __________________________

VIEW TIME

To view the time, press: [#]  [7].

CURRENT TIME:

08:15AM

SET TIME

To set the time, press: [#] [3]  [user 1 or 2 code]  [hr

1

] [hr

2

]  [min

1

] [min

2

]  [mnth

1

]

[mnth

2

]  [day

1

] [day

2

]

[year

1

] [year

2

]

(The user code is not required if so programmed by installer.)

TO VIEW AUTOARM TIME

To view the autoarm time, press: [#] [8]  [user 1 or 2 code].

AUTOARM TIME:

05:00PM

(The user code is not required if so programmed by installer.)

Summary of Contents for XL-2T

Page 1: ... 7 7 6HFXULW 6 VWHP 8VHU XLGH N9819V2 11 98 ARM STAY INSTANT AC LB READY 1 2 3 4 5 6 FIRE BURGLARY INSTRUMENTS INC Previous Menu ...

Page 2: ...HE SYSTEM ON 7 TURNING THE SYSTEM OFF 10 USER CODES 11 MISCELLANEOUS COMMANDS 12 TESTING THE SYSTEM 14 RECOMMENDATIONS ON SMOKE DETECTORS 15 EMERGENCY EVACUATION 16 GLOSSARY 17 FCC STATEMENT 20 TELEPHONE OPERATIONAL PROBLEMS 20 LIMITATIONS OF THIS ALARM SYSTEM 21 LIMITED WARRANTY 23 ...

Page 3: ...Check to make sure the system is ready Green READY light is lit 2 Press STAY 3 Enter your 4 digit user code The On Off ARM light and the STAY light will both light REMEMBER You must turn the system Off if you want to open the door or leave the premises after the exit time has passed TO TURN THE SYSTEM ON INSTANT MODE AND STAY INSIDE 1 Check to make sure the system is ready Green READY light is lit...

Page 4: ... your security system Your Security Company representative will suggest the model most appropriate for your premises and your needs The XL 2T is listed by Underwriters Laboratories for Household Fire and Burglary applications Throughout this manual the following conventions are used to represent the keystrokes required to perform the following functions STAY Press Button labeled STAY BYPASS Press ...

Page 5: ...l designated entry exit doors SEND HELP ALERT All keypads are equipped with emergency pair keys In order to activate the alert both keys must be pressed at the same time The type of keypad you have installed dictates which keys you press Your installer will show you how to activate these emergency keys The emergency keys used for all keypads are shown below The following SEND HELP ALERT is program...

Page 6: ...ER USER 2 MASTER USER 3 4 5 6 7 8 9 10 11 12 13 Door Strike Yes No If No _____________ If user 13 is not assigned to door strike then any user can activate the door strike 14 Only Turns System On Yes If No ____________ 15 Ambush Duress Code Yes If No ____________ Master Users can add change or erase other user codes MONITORING STATION INFORMATION Account Telephone ...

Page 7: ... Refer to the reference sheet for the time that has been set for your system WHEN THE SYSTEM IS NOT READY If the system is not ready to be armed the READY light will be off and the zone lights will show which zone or zones are not ready The following conditions will be indicated by the zone lights or described on the display Fast Blink Alarm Slow Blink Low Intensity Bypass Slow Pulse Trouble Solid...

Page 8: ...code When the system has been turned on successfully the On Off ARM light and the STAY light will be lit or the LCD will display ON STAY REMEMBER You must turn the system off if you want to open the door or leave the premises after the exit time has passed TO TURN THE SYSTEM ON IN INSTANT MODE AND STAY INSIDE In INSTANT STAY mode the perimeter portion of your burglar alarm system is on and the tim...

Page 9: ...ystem is turned off Press the BYPASS button Then enter your user code and the zone number 1 7 to be bypassed as follows BYPASS followed by your user code ZONE If the Quick Bypass feature has been enabled by the installer the user code is not required when bypassing zones NOTE Bypassed zones are NOT protected when the system is turned on After the bypass command has been accepted the keypad will so...

Page 10: ...ms occurred when the system was on or if a trouble condition exists the zone LED s will indicate it as follows Fast Blink Alarm Slow Blink Low Intensity Bypass Slow Pulse Trouble Solid On Not Ready or the LCD will display ALARM ZONE 1 FRONT DOOR Burglary alarms will sound a steady tone at the keypad s and fire alarms will generate a pulsing sound IMPORTANT If an intrusion has taken place while you...

Page 11: ...n emergency Ambush or Duress signal You may also have chosen to reserve one user code that is only allowed to turn the system on This code will not be able to turn the system off TO DELETE A USER CODE To delete a user press the Code button followed by the 4 digit master user code Enter the the user number then press to delete For example to delete user 3 do the following Master User Code User ID t...

Page 12: ...your system Off always requires a valid user code Press then 1 QUICK FORCED ON If programmed by your installer Quick Forced On allows you to turn the burglar portion of your alarm system on to the AWAY mode bypassing all zones that are not ready Press then 2 NOTE A valid user code is still required to turn the system off NOTE This feature is disabled on UL installations QUICK BYPASS If you have Qu...

Page 13: ...ad will prompt you for the required entries DOOR STRIKE To activate door strikes Press then 9 then Door Note that the installer may have assigned User 13 as the only user that can perform the door strike function where the door number is as follows 1 ________________________ 3 __________________________ 2 ________________________ 4 __________________________ VIEW TIME To view the time press 7 CURR...

Page 14: ...nth In order to test your backup standby battery the following procedure should be followed 1 Unplug the transformer from the AC outlet by removing the restraining screw that secures the transformer to the wall NOTE The screw is not present on the models sold in Canada 2 Observe that the AC indicator light on the keypad goes off 3 Activate your alarm by performing the above SYSTEM TEST Remember to...

Page 15: ...mediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you install heat or smoke detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basements and attached garages DINING KITCHEN BEDROOM BEDROOM BEDR...

Page 16: ... and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check your alternate escape route If the door is cool open it cautiously ...

Page 17: ...er contacted by your security system over the telephone and or other communication channels when alarms are activated if your system is programmed to communicate alarms off site The central station will follow their procedures and your instructions for contacting the proper authorities when a signal is received CHIME FEATURE An optional feature that causes the keypad to chime for one second when s...

Page 18: ... and ready they are not affected in any way by turning the burglary portion of your security system on or off Other terms used are armed system is on and disarmed system is off See ON INSTANT ON STAY and STAY ON OFF INDICATOR Red light in the upper portion of the keypad labeled Armed When lit some part of the burglar alarm system is on when not lit the burglary portion of the system is off ON STAY...

Page 19: ... link to the monitoring agency central station 2 the keypad s which provide you with system status and allow you to input commands 3 security sensors such as door and window contacts motion sensors smoke detectors and other sensors as required to detect intrusion fire and other conditions for your premises USER CODE A user code is a 4 digit code that is required to operate the system The system su...

Page 20: ...technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User Guide Unauthor...

Page 21: ...not reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may n...

Page 22: ... if the system responds to the emergency as intended occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not respond appropriately This equipment like other electrical devices is subject to component failure Even though this equipment is designed to last as long as 10 years the electronic components could f...

Page 23: ...N NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or conseq...

Page 24: ... 1 9 l N9819V2 11 98 FIRE BURGLARY INSTRUMENTS INC Subsidiary of PITTWAY CORPORATION 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION ...

Reviews: