4
Figure 6.2
Figure 6.1
BIB SUPPLY
A. Fabricate two (2) 1/4 inch supply lines for connecting the unit to the syrup pumps.
B. Connect the lines to the bulkhead fittings labeled "SYRUP 1 LEFT" and "SYRUP 2 RIGHT"
located at the rear of the unit (see Figure 5.2).
C. Do not turn on the CO
2
at this time.
FIVE GALLON (FIGAL) TANK SUPPLY
A. Fabricate two (2) 1/4 inch supply lines for connecting the unit to the syrup tanks.
B. Connect the lines to the bulkhead fittings labeled "SYRUP 1 LEFT" and "SYRUP 2 RIGHT"
located at the rear of the unit (see Figure 5.2).
C.
When using five gallon (figal) syrup tanks, a Syrup Restart Valve (SRV) and tank couplers
must be used on each line. Warranties will be void if an SRV is not installed.
1.
The "OUT OF" devices in the machine will not function properly without the use of a Syrup
Restart Valve. If the "OUT OF" devices do not function, the machine will supply only water
to the product cylinder and it will freeze up.
2.
When replacing a figal, insure that the syrup line to the dispenser is attached to the figal
before the CO
2
line is attached to the figal. This will allow the SRV to work properly.
3.
To operate the SRV, press the restart button after syrup tank is changed. The red light
beside each chamber will then go out and product will refreeze.
D.
Do not turn on the CO
2
at this time.
6.
STARTING THE UNIT
Access
Panel
Electrical Box
Cover
6.1
INITIAL POWER-UP
A. Insure the electrical power is disconnected from the unit.
B. Open the front marquee door by disengaging the latch located behind the right side of the door.
C. Using a Phillips head screwdriver, remove the stainless steel access panel located below the
keypad (see Figure 6.1).
D. Remove the splash plate and electric box cover (see Figure 6.2).
E. Plug unit in to the electrical power. The graphics display should illuminate. Check for the
display of information on the LCD control panel (this will read "COPYRIGHT" on bottom line of
LCD display).
F.
With voltage meter, check voltage at contactor between L1 & L2 and record. Also check
between L1 and ground bar, and between L2 and ground bar, to ensure highest voltage leg is
on L1 (see Figure 6.3 and Section 14.3).
H. Access the “Line Voltage” readout in the "SERVICE MENU\READOUTS\COMMON
READOUTS" section of the LCD menu.
If the “Readout” voltage is more than two (2) volts
different than the voltage across L1 and L2, the "Voltage Offset" must be changed.
Failure
to do so will cause performance loss of the unit. To change the "voltage offset", go to
"SERVICE MENU\MACHINE SETTINGS\COMMON SETTINGS" and enter the difference
between the meter reading and the “Line Voltage” readout to make the LCD voltage reading
match the L1 and L2 voltage. Reinstall the splash plate and electric box cover.