2.
Press the “SELECT” button, “L Side Settings” displays. If “R Side Setting” is desired, press
“Forward”.
3.
Press “SELECT” and “Level Control” displays.
4.
Press the “SELECT” button and the default setting of “3” begins to flash. The level is raised
by pressing the “FWD” button and lowered by pressing the “BACK” button. When the
desired number is reached, press “SELECT” and the new setting stops flashing and is set
into the computer.
D. When settings are complete, press the "CANCEL" button until "Copyright" displays.
NOTE
If the machine continues to yield a drink that is too liquid or too hard after changing level control
settings, it may be necessary to adjust the THAW and FREEZE settings (refer to Section 11,
Changing Factory Thaw And Freeze Settings).
11. CHANGING FACTORY THAW AND FREEZE SETTINGS
11.1 BEFORE CHANGING THAW AND FREEZE SETTINGS
A.
Each machine ships with THAW and FREEZE values preset. These values should be correct
for normal operation of the machine and are designed to produce a drink temperature
between 24 and 28 degrees. Before making any changes to THAW AND FREEZE
settings, check drink temperature. If drink temperature is within correct range, DO NOT
CHANGE THAW-FREEZE SETTINGS.
B.
Before changing the THAW or FREEZE settings,
verify that the level control and Brix settings
are properly set. After verifying the “Level Control”, defrost both chambers by pressing the
“DEF” buttons located on the control panel. The machine may correct any problems with drink
quality after going through a defrost cycle.
1.
After the defrost and refreeze cycle, the compressor may cycle on and off several times to
ensure that the product is uniformly frozen.
Wait several minutes, and dispense several
drinks, before judging the quality of the product.
2.
The product should freeze to a proper frozen texture, thaw, and refreeze to the same
general texture. The compressor turns on when the thawed product requires refreezing and
shuts off when the product is frozen enough.
3.
If the product is freezing too cold (below 24°F), the THAW - FREEZE value may be
increased. If the product is not cold enough (above 28°F), the THAW - FREEZE value may
be decreased.
Use the recommended settings that follow when making adjustments to the
THAW - FREEZE value.
Recommended THAW-FREEZE Settings
Figure 11.1
11.2 CHANGING THAW AND FREEZE SETTINGS
The THAW-FREEZE values should only be changed if the drink quality is not as expected. Use the
following steps to change THAW-FREEZE settings as necessary. Before changing the
THAW-FREEZE settings, verify that the brix and level control settings (see Section 10.1) are
properly set. THAW-FREEZE settings may not need changing if corrections are made to the level
control settings.
HIGHER THAW/FREEZE SETTING
HIGHER THAW/FREEZE SETTING
HIGHER THAW/FREEZE SETTING
FACTORY SETTING
LOWER THAW/FREEZE SETTING
LOWER THAW/FREEZE SETTING
LOWER THAW/FREEZE SETTING
6
5
4
3
2
1
0
WARMER
DRINK
TEMPERATURES
COLDER
DRINK
TEMPERATURES