3.
Remove the air filter cover (2).
4.
Disassemble the covering (1).
5.
Unscrew the fastening screws (1).
6.
Remove the valve cover (2) with gasket.
Valve clearance:
Intake valve (IN)
0.20 mm (0.008 in)
Exhaust valve (EX)
0.20 mm (0.008 in)
1.
Crank the engine, until the exhaust valve (EX) is fully open.
2.
Check the valve clearance on the intake valve (IN) with a
feeler gauge (1), adjust if necessary.
3.
Crank the engine further, until the intake valve is fully open.
4.
Check the valve clearance on the exhaust valve, adjust if
necessary.
Fig. 66
Fig. 67
Checking the valve clearance
Fig. 68
Maintenance – Annually / every 250 operating hours
DRP45DX
78
Summary of Contents for DYNAPAC DRP45DX
Page 2: ...2 ...
Page 6: ...Table of contents DRP45DX 6 ...
Page 7: ...1 Introduction Introduction DRP45DX 7 ...
Page 11: ...2 Technical data Technical data DRP45DX 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DRP45DX 15 ...
Page 40: ...Concerning your safety Signage DRP45DX 40 ...
Page 41: ...4 Indicators and control elements Indicators and control elements DRP45DX 41 ...
Page 43: ...5 Checks prior to start up Checks prior to start up DRP45DX 43 ...
Page 49: ...6 Operation Operation DRP45DX 49 ...
Page 56: ...Operation Parking the machine in secured condition DRP45DX 56 ...
Page 57: ...7 Loading transporting the machine Loading transporting the machine DRP45DX 57 ...
Page 61: ...8 Maintenance Maintenance DRP45DX 61 ...
Page 96: ...6 Check the oil levels 7 Clean the machine thoroughly Maintenance As required DRP45DX 96 ...
Page 97: ...9 Troubleshooting Troubleshooting DRP45DX 97 ...
Page 106: ...Troubleshooting Malfunctions during operation DRP45DX 106 ...
Page 107: ...10 Disposal Disposal DRP45DX 107 ...
Page 109: ......
Page 110: ......