Favero FA-07 User Manual Download Page 5

ENGLISH

3.

FA-07 KEYBOARD

With reference to  Fig. 3,  the following is a description of each key’s
function.

Select (upon rotation) the weapon in use; 4 possibilities:

FOIL,

SABRE,

ÉPÉE,

ÉPÉE-TRAINING;

this is used in training for signaling hits in rapid succession.
After   a   determinate   time   the  

FA-07

  prevents   the   annoying

and continuous noise that occurs in sabre and foil when both
fencers are not connected, and the white lights are switched
off in order to save energy. Once a fencer reconnects, signals
are switched back on.

Select (upon rotation) rearmament time from the following: 1, 3, 5 seconds and Manual.

Chronometer start time. Can be selected (upon rotation) from 1 to 9 minutes. The same function can be made via the
remote control by pressing [

Alt-1

] + [

TIME

_

SET

].

At the beginning of each match the time indicated is loaded on the chronometer via the remote control, by either
pressing the [

LOAD

_

TIME

] key or the [

Alt-1

] + [

RESET

_

ALL]

 keys.

Select (upon rotation) from 4 sound levels: 0 (sound off), 1, 2, 3 (max volume level).

Activate (=YES) or deactivate (=NO) the automatic score increase if a hit is made when the selected weapon is ÉPÉE
and the chronometer is counting.

Function key [

F3

]. See chapter 7.1.

Insert the RESERVE fencer on the left side, in team competitions. On the FA-07 display panel the name of the fencer
will   be   replaced   by   the   words   “RESERVE”.  The   key   is   active   when   the   competitions   are   managed   via   a   LAN
connection, after confirming the match by the [

Alt-1

] + [

BEGIN

] keys.

Same as with [

F1

] key but for the right side.

Increase the number of medical interventions for the corresponding fencer: [0, 1, 2 3]. After 3, it resets to zero. This is
useful when there is a connection via LAN and you wish to send information to the central system .

Select (upon rotation) fencer’s status:

“A” = Abandon. In the case of withdrawal or absence .

“E” = Exclusion. In the case of disqualification by the referee.

“V” = Victoire. Appears automatically if the fencer has a higher score than his/her opponent.

“D” = Défaite. Appears automatically if the fencer has a lower score than his/her opponent.

“-”  = Undefined. Appears automatically in the case of a draw or if the other fencer’s status is Abandon or Exclusion .

A referee may select Abandon or Exclusion when there is a LAN connection and they wish to communicate such
information to the central system (see chapter 6.5).

Programming and test keys. See chapter 5.

940-M06-EN FA-07 Manual

Page 5/ 16

FAVERO ELECTRONICS SRL

Fig. 3: FA-07 Keyboard

Rear m.

time

(sec)

Sound

Level

F 1

F3

F2

Medical

V/D

Abandon

Exclusion

PROG

ENTER

EXIT

NEXT

PREVIOUS

+

Summary of Contents for FA-07

Page 1: ...keys 6 4 5 Battery charging 8 4 5 1 Low battery indication 8 5 PROGRAMMING TEST MENUS 9 5 1 Introduction 9 5 2 Description of programming steps 9 5 3 Description of tests 9 6 OPERATION VIA LAN 11 6 1 Preliminary information 11 6 2 Software for the central system for managing competitions 11 6 3 LAN connections 11 6 4 IP addresses and checking connection status 12 6 5 Matches managed via LAN 12 6 5...

Page 2: ...0 01 FA 07 Scoreboard without accessories Art 952 FA 07 remote control Art 858 2 5m Cable for Serial Data Art 859 15m Cable for Serial Data Art 954 Power Supply 90 264V 12Vdc 2 5A Medical Art 828 Rechargeable battery 12Vdc 7Ah Art 829 Battery charger for Art 828 battery Art 880 Doubler for SERIAL DATA Art 856 Power cord with clamps for connecting to a car battery Art 948 Carrying case for Tower Li...

Page 3: ... purchase agreement and includes free repair of all defects found in materials or in construction the warranty does not cover delivery or transportation costs The portable power supply Art 954 provided with the FA 07 and the optional battery Art 828 are not covered by the warranty 1 4 Power supply Power supply voltage 12Vdc 10 6 14 5Vdc Consumption 0 5A typical 0 85A max without the Tower Lights 2...

Page 4: ...s follows 1 Selected weapon and version or else temporary notification of faults or other information 2 Rearmament time 1 3 5 Man Rearmament can take place automatically after 1 3 or 5 seconds or else manually 3 Start time minutes of chronometer 4 Nationality of fencers 5 Names of fencers as with nationalities the names of the fencers appear only when the FA 07 receives the information from the ce...

Page 5: ...See chapter 7 1 Insert the RESERVE fencer on the left side in team competitions On the FA 07 display panel the name of the fencer will be replaced by the words RESERVE The key is active when the competitions are managed via a LAN connection after confirming the match by the Alt 1 BEGIN keys Same as with F1 key but for the right side Increase the number of medical interventions for the correspondin...

Page 6: ...p P 03 select Block Remote Control YES see chapter 5 2 Remember to unblock this function at the end of the competition otherwise future users who are not familiar with or who do not remember this function might assume that the remote control is not working properly 4 3 Remote control indications There are 2 red lights on the remote control see Fig 5 Transmission light signals each transmission If ...

Page 7: ...f matches Fx not used Alt 1 WEAPONS effectuate the change of weapon in the same way that the corresponding key on the FA 07 keyboard does Fencers_swap inverts all the visual displays regarding the two fencers This is used when fencers change positions Alt 1 1sec decrease the value of the chronometer by 1 second to allow for corrections to be made During the last 10 seconds time decrease is display...

Page 8: ...ed A totally depleted battery is recharged in circa 7 hours while a charged battery lasts circa 300 hours of competition time We suggest charging the battery at least once a year if the remote control is not used 4 5 1 Low battery indication If the remote control battery is low the FA 07 s graphic display panel will switch off for a brief moment and the message Remote Control Battery Low will appe...

Page 9: ...meter P 04 IP 000 000 000 000 254 254 254 254 When a LAN connection is used each apparatus must have a different IP address We suggest using a number from 192 168 000 020 to 192 168 000 254 if not already in use by other devices Use the key to select the number you wish to modify and the keys and to modify it P 05 Port number 01025 65535 This number is used for connection to the LAN We suggest tha...

Page 10: ...all the contact combinations that take place between fencers It can also be useful to the user for distinguishing if the indications of faults are due to failure of the internal circuits or to defects in the external connections The display panel see Fig 12 shows 12 values in the three columns to the left and in the far right column the corresponding values Higher H Middle M Lower L and Deviation ...

Page 11: ... Alt 1 PREVIOUS for the data from the previously concluded match in order to correct any possible errors The central system decides whether to accept the request or not For more information on management of the match via LAN see chapter 6 5 6 2 Software for the central system for managing competitions Communication between the central system and the various FA 07 apparatuses connected to the LAN t...

Page 12: ...alue etc for managing team competitions where the matches which immediately follow continue with the previous scores and the match number is automatically determined by the central system The reception of all data is also necessary when a previously interrupted match is recalled see chapter 6 5 4 Information regarding the new match may include the time the match is scheduled to begin if so the tim...

Page 13: ...em has been informed of the match end and the MATCH Running light has been switched off a new match can be requested as described in chapter 6 5 1 6 5 4 Correcting a previously sent match Via the Alt 1 PREVIOUS keys of the remote control the referee can ask the central system for the data pertaining to the previously concluded match in order to make eventual corrections The central system will dec...

Page 14: ...Ethernet port This port allows the FA 07 to be connected A directly to a PC for updating software as described in chapter 8 B to a LAN in order to manage the entire competition via the central system as described in chapter 6 The Ethernet port has a 1500V isolation to protect fencers from any dangerous high voltages 7 4 Tower Lights Connection The pair of Tower Lights is an optional accessory and ...

Page 15: ...r PC Type in the IP address 192 168 1 230 in the browser s address bar See Fig 19 6 On the page that appears on your computer see Fig 20 click on the Choose button to browse the computer s folders and select the previously saved update file of the type FA 07_0100_0201 bin Then click on Open to confirm your choice 7 Launch the software update program by clicking on Upload At the end of the operatio...

Page 16: ...ENGLISH FAVERO ELECTRONICS SRL Page 16 16 940 M06 EN FA 07 Manual ...

Reviews: