Gasket
The equipment shall be assembled with gaskets according to NF EN 1514 and
NF EN 12560 standards and depending on flange type.
Spiral wound gaskets are forbidden for flanges rating below class 300 or PN 63.
Flange bolting
The material of flange bolting shall be chosen in ASTM A 193 B7 (rods) and
ASTM A 194 2H (nuts) according to EN ISO 898-1 standard for temperature
between -45°C and +480°C.
Tightening torque
Recommended tightening torque for Klingersil gasket type
Bolt size
Nm
Bolt size
Nm
M14
110
M30
1130
M16
170
M33
1520
M20
330
M36
1960
M24
570
M39
2525
M27
828
M42
3135
The link of a flowmeter equipped with a flow straightener is tightened at the factory but
must be checked and retightened before commissioning. A label affixed to the flanges of
this link calls attention to this requirement.
Summary of Contents for FH8500
Page 1: ...FH 8500 1 ...
Page 2: ......
Page 6: ...FH 8500 4 4 4 4 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 26: ...FH8500 24 24 24 24 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 36: ...FH8500 34 34 34 34 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 88: ...FH8500 86 86 86 86 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 90: ...FH8500 88 88 88 88 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 91: ...89 89 89 89 Appendix Appendix Appendix Appendix II II II II Lifting Arrangement Drawing ...
Page 94: ...FH8500 92 92 92 92 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 98: ...FH8500 96 96 96 96 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 102: ...FH8500 100 100 100 100 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 114: ...FH8500 112 112 112 112 TEC 05 03 09 412522 Revision index I 09 07 2013 ...
Page 115: ...113 113 113 113 Personal Personal Personal Personal notes notes notes notes ...