User manual AD CM M
Page 18 of 20
Turning the potentiometer CCW will increase the acceleration time and decrease the
acceleration rate (t
acc
and
t
dec
), the motor speed increases/decreases slower
4.4
Operation of the AD CM M3S
•
The Buttons RUN/STOP allow to operate the motors manually.
See details below.
The functions RUN/STOP are also available on the COMMAND connector and are operating in parallel to
the switches.
•
Jumpers VCO and ADJ in Position A involve that the motor starts upon power up and the inputs RUN,
STOP have no function
•
Jumper VCO in Position A, Jumper ADJ in Position B involve that the motor will react on the inputs RUN,
STOP
•
Jumper CK will set either internal or external clock generator
4.4.1 Switches/buttons RUN and STOP
RUN Function:
The motor starts to accelerate when RUN is activated or pressed.
Note
the PIN 5 on the COMMAND connector has the same function, in case that the PIN 5 is activated (5 to
24VDC applied), the RUN button has no function.
STOP Function:
The motor starts to decelerate when STOP is activated or pressed.
Note
the PIN6 on the COMMAND connector has the same identical function, in case that the PIN 6 is
activated (5 to 24VDC applied), the STOP button has no function
4.4.2 Jumper ADJ = Adjust
Position A
The motor rotates on the set FMIN and FMAX operation speed settings.
Button RUN pressed:
Acceleration from FMIN speed to FMAX speed
Button STOP pressed:
Motor will decelerate but will continue to run at the speed setting of the
FMIN.
MIN
Time
Speed
Start
Stop
MAX
t
acc
t
dec
Position B
The motor rotates on the set FMIN and FMAX operation speed settings but will stop automatically
after the deceleration (when the FMIN speed has been reached)
Button RUN pressed:
Acceleration from MIN speed to MAX speed
Button STOP pressed:
Motor will decelerate and stop rotating
Start Stop