6
Speed setpoint input via analog voltage
6.1
Note
This configuration ist standard as delivered condition.
The setpoint speed is proportional to the voltage U
nsoll
, which can be adjusted via the potentiometer.
The voltage range of U
nsoll
is defined from 0 – 10 V. The maximum speed value at 10 V can be adjust-
ed via the parameter NsetMax.
Direction of Rotation
6.2
The direction of rotation of the motor depends on switch S1 and S2.
S2
S1
9
5
6
1
LED1
LED2
0V
ON
OFF
Ext.
U
nsoll
Int.
RIGHT
LEFT
U
P
10V
U
nsoll
PROG
MOT
Mode
DIR
2,54
U
P
= U
mot
I
mot
U
P
U
mot
U
nsoll
DIR
FG
OK
Power
on
GND
Motoranschlüsse
U
P
= U
elo
USB
RS232
1
1
1
1
1
2
2
3
M09
GND
U
elo
U
mot
To change the direction of rotation, turn switch S1 to “MOT” and choose the direction via switch S2.
If S1 is turned to “PROG” the motor will always rotate clockwise.
Note
For detailed descriptions of all parameters and settings see the instruction manual of the speed con-
troller.