background image

6

 

 

6.  Power Connection

 

 

 

 

  Be  sure  to  connect  the  ground  FG 

terminal  to  a  class-3  ground  (Ground 
resistance  should  not  exceed  100Ω). 
Try  to  make  the ground wire as  short 
as possible. 
 

  Use 28

12 AWG (0.5

1.5 mm

2

) wire 

for the power connections. 

 

 

7.  Termination Switch 

  P5150NH HMI has a built-in termination resistor switch.   

To  enable  or  disable  the  termination  resistor  please  follow  the  configuration 
shown in the table below. The termination switch is for COM3 [RS-422 / RS-
485] and COM4 [RS-485]. 
 

  Configuration of Termination Resistor Switch. 

 

 

 

Termination Resistor 

No. 

COM3 [RS-422] 

COM3 [RS-485] 

COM4 [RS-485] 

Enable 

Disable 

Enable 

Disable 

Enable 

Disable 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

ON 

OFF 

ON 

OFF 

OFF 

OFF 

ON 

OFF 

ON 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

Summary of Contents for P5150NH

Page 1: ...el is damaged avoid contact with the leaked liquid crystal If the liquid crystal spills on clothing or skin use soap and wash off thoroughly In case of eye contact the liquid hold the eye open flush with plenty water and get medical attention as soon as possible Do not touch any terminals while the power is on Otherwise it may cause injury due to electrical shock Disconnect the power supply before...

Page 2: ...ge the touch screen Do not use the output signal of the device as any safety function or system emergency stop It may result in personal injury or equipment damage if a malfunction of the touch occurs 1 4 Maintenance and Service The agreed guarantee applies Only qualified personnel should make repairs and perform maintenance Disconnect the device from the power supply before carrying out cleaning ...

Page 3: ...le HB1 PLC Connector COM3 COM4 Termination Switch HB1 PLC Screw Hole Power Connector COM3 COM4 Pluggable Terminal Block Mini USB Connector USB Connector Ethernet RJ45 Connector COM1 DB 9 Male Connector Micro SD Card Slot Audio Phone Jack W 365 mm H 292 mm D 54 7 mm ...

Page 4: ...II Equipment type Permanently connected Fixed I O Port Serial 1 Connector D Sub 9 Pin COM1 RS 232 4W Serial 2 Connector Pluggable Terminal Block COM3 RS 422 485 COM4 RS 485 LAN 10M 100M USB USB2 0 Type A Host x1 USB2 0 Type mini B Device x1 Micro SD Yes Audio Yes PLC Extension HB1 main units B1 extension modules Termination Switch Yes For RS 422 485 Power Power Input 24VDC 20 Isolated Power Consum...

Page 5: ...stallation Procedures Push the HMI into the cutout until the waterproof ring contacts the plate Insert a hook into each mounting hole on the HMI and then tighten the screws evenly with a moderate torque Failure to tighten the screws may cause the HMI to fall malfunction or short circuit Excessive tightening may cause deformation The necessary torque is about 0 16N m ...

Page 6: ...tion resistor switch To enable or disable the termination resistor please follow the configuration shown in the table below The termination switch is for COM3 RS 422 RS 485 and COM4 RS 485 Configuration of Termination Resistor Switch Termination Resistor No COM3 RS 422 COM3 RS 485 COM4 RS 485 Enable Disable Enable Disable Enable Disable 6 OFF OFF OFF OFF ON OFF 5 OFF OFF OFF OFF ON OFF 4 ON OFF ON...

Page 7: ...ctor PIN COM1 RS 232 1 NC 1 2 RX 3 TX 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC 1 NC No Connection Pluggable Terminal Block PIN COM3 RS 422 COM3 RS 485 COM4 RS 485 1 NC NC DATA 2 NC NC DATA 3 GND GND GND 4 RX NC NC 5 RX NC NC 6 TX DATA NC 7 TX DATA NC ...

Page 8: ...t use the FATEK PLC connector to connect the main unit and then insert into the HB1 connector hole on the back cover of the HMI to complete the connection 26FL NO 29 SEC 2 JUNGJENG E RD DANSHUEI DIST NEW TAIPEI CITY 25170 TAIWAN R O C TEL 886 2 2808 2192 FAX 886 2 2809 2618 E mail sales fatek com tech fatek com Website www fatek com AUTOMATION CORPORATION ...

Reviews: