Functional Description
VIM301
V I M 3 0 1 U s e r M a n u a l
23
© 2 0 1 5 F a s t w e l v . 0 0 2
3.2.8
Flat Panel 1 Connector
A display with parallel discrete Flat Panel interface can be connected to the module using XP5
header (AMP 104069-6, mating connector AMP 111196-9). 9 / 12 / 18 / 24-bit panels are
supported. Panel type is selected using SA1 DIP switch, while the power is off. XP5 header pinout
is presented in the table below.
Table 3.10:
Flat Panel 1 (XP5) Connector Pinout
Pin#
Signal
Pin#
Signal
1
GND
2
GND
3
VBIASEN
4
FPVDDEN
5
DATA0
6
DATA1
7
DATA2
8
DATA3
9
DATA4
10
DATA5
11
DATA6
12
DATA7
13
DATA8
14
DATA9
15
DATA10
16
DATA11
17
DATA12
18
DATA13
19
DATA14
20
DATA15
21
DATA16
22
DATA17
23
DATA18
24
DATA19
25
DATA20
26
DATA21
27
DATA22
28
DATA23
29
EN
30
DE
31
SCLK
32
VSYNC
33
GND
34
HSYNC
35
+5V
36
+5V
37
–
38
–
39
–
40
–
In the table above:
«–» – Not used.
Figure 3.10:
Flat Panel 1 (XP5) Connector