Z3 SERIES
• Z3T-2500 □□
• Z3R- Q200 □□
• Z3R- 400 □□
• Z3D- L09 □□
• Z3D- 100 □□
INSTRUCTION MANUAL
● Please confirm if specifications fulfill your needs.
● Please read this manual carefully before the use and keep this for
future reference.
Photoelectric Sensor
DIMENSIONS
Brackets for installation are optional and not included in this kit.
(Not standard accessory and please purchase if needed.)
φ 3.8 2m Cable
2-M3 P0.5
Output indicator
(
orange
)
Stable indicator
(
green
)
Sensitivity adjuster
L/ON , D/ON selector
11
20
25.4
31
11.9
1.2
7.3
4.4
16
10
21.2
15.5
7.7
12.4
21.2
Sender
Through beam sender
・
Receiver
Limited range Receiver
19
18.8
Optical axis
(Sender,Receiver)
BEF-W100-B
Cable type : When using brackets of BEF-W100-B (option)
φ 3.8 2m Cable
2-M3 P0.5
Output indicator
(
orange
)
Stable indicator
(
green
)
Sensitivity adjuster
L/ON , D/ON selector
11
20
25.4
31
11.9
1.2
7.3
4.4
16
10
21.2
15.5
7.7
12.4
21.2
Sender
Through beam sender
・
Receiver
Limited range Receiver
19
18.8
Optical axis
(Sender,Receiver)
BEF-W100-B
Connector type : When using brackets of BEF-W100-A (option)
出力表示灯(橙)
安定表示灯(緑)
感度調整ボリウム
ライトON/ダークON切替スイッチ
2-M3 P0.5
M8 4-pin connector
1.2
5.8
12.6
1.7
5.2
32.4
3
13.7
4.4
8.2
14
18.8
19
11
29.3
20
25.4
0.7
31
11.9
26
Sender
Through beam sender
・
Receiver
Limited range Receiver
BEF-W100-A
Optical axis
(Sender,Receiver)
Adjusting the potentiometer
①
A
A
B
B
C
Set the detectable object at the detection position and turn the potentiometer
from MIN toward MAX until the output indicator(orange) light up. Call it
position A.
②
A
A
B
B
C
Remove detectable object and turn the potentiometer from MAX toward MIN
position where the output indicator(orange) is extinguished. Call it position B.
③
A
A
B
B
C
Point C midway between A and B is the optimum sensitivity position. The
position A and B may reverse by types and detecting situation .
Reflectors(option)
For Retro Reflective or Transparent object use only
Please confirm appropriate type considering sensing distance and conditions to use.
Reflectors are optional and not included in this kit.
(Not standard accessory and please purchase if needed.)
●
Standard Type Type:V-61
Sensing distance:0.01~4m(Retro Reflective Type)
Sensing distance:0.01~2m(
Transparent objects
Type)
●
Small reflector Type:V-42
Sensing distance:0.01~2.4m(Retro Reflective Type)
Sensing distance:0.01~1.4m(
Transparent objects
Type)
47
51.6
20
40
61.6
51
47
5
4.4
8.6
3
35
31
31
35
42
3.65
25
3.5
8
2- φ3.6
●
Small reflector Type:P45A
Sensing distance:0.01~1.4m(Retro Reflective Type)
Sensing distance:0.01~0.7m(
Transparent objects
Type)
2.2
8.4
33.3
45
54
φ7
φ3.5
12.4
6.2
SPECIFICATIONS
Through beam
Retro ref.
Diffused ref.
Transparent objects
Limited range
Cable type
Z3T-2500(N/P)
Z3R-400(N/P)
Z3D-100(N/P)
Z3R-Q200(N/P)
Z3D-L09(N/P)
Connector type
Z3T-2500C(N4/P4) Z3R-400C(N4/P4) Z3D-100C(N4/P4) Z3R-Q200C(N4/P4) Z3D-L09C(N4/P4)
Nominal distance
*1
25m
0.01~4m
0~1m
0.01~2m
10~90mm
Light Source
Red LED
Spot size
φ 1800㎜ /25 m
φ 280㎜ /4 m
φ 75㎜ /1m
φ 140㎜ /2 m
φ 8㎜ /90㎜
Supply voltage
DC10 ~ 30V Including ripple (P-P) 10%
Current consumption
Sender : 20mA max
20mA max
25mA max
20mA max
Receiver : 15mA max.
Response time
500µs max
Hysteresis
ー
ー
20% Max.
ー
10% Max.
Control output
NPN/PNP Open collector 100mA max. / DC30V max. (Residual voltage 1.8V max.)
Operation mode
Light ON, Dark ON Selectable by switch
Sensitivity adjustment
1 turn volume
Indicator
Output indicator (orange LED) / Stable indicator (green LED)
Ambient temp. / humidity
-25 ~ 55℃ /35 ~ 85%RH (No condensation or freezing)
Storage temp. / humidity
-40 ~ 70℃ /35 ~ 95%RH (No condensation or freezing)
protection category/material
IP67 / Case : ABS , Front Cover : PMMA
*1 Sensing distance showed in above table is typical value in each type.
・
Retro ref.
/
Transparent objects types
: Reflector V-61(option)
・
Diffused ref. type
: White paper 200x200mm
・
Limited range type
: White paper 100x100mm
INPUT AND OUTPUT CIRCUIT DIAGRAM
NPN type
Through beam emitter
Protection
Main circuit
Load
circuit
4
1
1
3
4
3
M8 3pin
M8 4pin
Brown
Blue
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
①
DC10
~
30V
③
0V
Protection
Main circuit
Load
circuit
Main circuit
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
Protection
Main circuit
Load
circuit
4
1
1
3
4
3
M8 3pin
M8 4pin
Brown
Blue
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
①
DC10
~
30V
③
0V
Protection
Main circuit
Load
circuit
Main circuit
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
PNP type
Connector pin No.
Protection
Main circuit
Load
circuit
4
1
1
3
4
3
M8 3pin
M8 4pin
Brown
Blue
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
①
DC10
~
30V
③
0V
Protection
Main circuit
Load
circuit
Main circuit
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
Protection
Main circuit
Load
circuit
4
1
1
3
4
3
M8 3pin
M8 4pin
Brown
Blue
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
①
DC10
~
30V
③
0V
Protection
Main circuit
Load
circuit
Main circuit
Blue
Black
Brown
①
DC10
~
30V
③
0V
④
Control output
①・・・DC10~30V
③・・・0V
④・・・Control output
Attachment
•
Tightening torque need to be under 0.5N•m.
•
Use M3 screw to mount.(more than 7.5mm insert)
Safety Precautions
●It is dangerous to wire or attach/remove the connector
with the power on. Make sure to turn off the power before
operation.
●Make sure to use the product with the protective cover
attached and closed.
●Installing in the following places may result in malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil.
4. A place suff ered from heavy vibration or impact.
●The product is not designed for outdoor use.
●Do not use the sensor in transient state after power on
(approx. 100 ms).
●Do not wire with the high voltage cable or the power line.
Failure to do this will cause malfunction by induction or
damage.
●The sensor performance or digital display values may
depend on the individual units or the condition of detected
product.
●This product is not an explosion-proof construction.
Do not use the product under fl ammable, explosive
gas or liquid environment.
● Do not use the product in water.
● Do not disassemble, repair, or convert the product.
Failure to do this may cause failure, fi re, or electric shock.
● Operate within the rated range.
This product cannot be used as a safety device
to protect human body.
bracket(option)
BEF-W100-B