Process Controllers
FAST Lit. Part No. 229-51311 Rev. E (MANAGER)
24SEP2010
Page 7
2005-2010 Food Automation – Service Techniques, Inc. All Rights Reserved
This document contains confidential information. The dissemination, publication,
copying, or duplication of this document without prior written authorization is
strictly prohibited.
Programming the (FASTRON.)
VC-210 Controller
Programming Mode for the Vision Controller is entered by pressing the “P” key for three (3) seconds. Multiple
programming modes are available on the VC-210 as follows:
Passcode
Access Level
Sy
st
em
R
eci
pe
Pro
dN
ame
Li
br
ar
y
A
la
rm
Li
br
ar
y
C
lo
ck
/Da
te
SMS
A
cti
va
te
In
st
ant
O
n
SC
K
A
ddr
es
s
6647
Manager
X
X
X
X
X
X
X
NOTES:
•
Pressing the “P” key saves the previous parameter.
•
If no key is pressed within 2 minutes while in Programming mode, the controller will automatically
return to idle mode.
•
All scrolling will loop back through allowed values.
Changing the Menu Strip on a (FASTRON.) VC-210
Process Controller
1
•
Turn off the fryer power.
2
•
With a flat screwdriver, remove the two screws that secure the bezel of the
VC-210 in place. Remove the bezel.
3
•
Remove the existing menu strip(s) by lifting the tab and pulling the menu
strip out from the right side of the controller.
4
•
Using the tab as a guide, slide the new menu strip in.
5
•
Replace the bezel and screws that secure it to the controller.
6
•
Turn on the fryer power.
Replacement Parts List
Part Number
Description
150-10202
1/4-20X3/4" SLOT RD HD BLK O
150-11025
NUT 1/4-20 TINNERMAN SPRING
214-50291
SHEETMETAL BEZEL
214-50660R57
OVERLAY
214-51003-57