FN ICON CALIBRATION AND REBUILD INSTRUCTIONS 

 

 

    Roseville, MN 

     Ph: 1-800-444-2373 
     Fax: 651-645-7390 

     www.fastestinc.com 

                                                             Page 

3

 of 

5

                                                                                                                                                                                                    WP158 Rev C, 12/13/2021  

 

 

        

AT REST 

TOO FAR 

 
 

The input is asserted by applying 24V. This can be accomplished by pressing the button 
on a FasTest Programming tool, or by using a 24V PLC signal or other 24V logic output.  

3. 

Flash input 4 times quickly to enter programming mode. Connector will flash 3 times indi-
cating programming mode. 

Note: If the first calibration point is not set within about 30 

seconds, the connector will return to operational mode.

 

4. 

Do not apply pressure to the handle.

 Hold input line high until indicator begins to flash, 

about 2 seconds. The first calibration point will be recorded when the input is released.  

5. 

Squeeze lever handle until the back of the main seal groove on the collet’s lines up with 
the  flat face  of  the  front  body.  (See  next  section  for  pneumatic connectors).  It may  be 
helpful to remove the main seal for steps 5 and 6 

ONLY

Note: this location will change depending on thread size and fitting type. 
 
 
 
 
 
 
 
 
 
 
 

6. 

Apply 24V signal to the input line until the indicator begins to flash, about 2 seconds. Re-
lease the input line to record the second calibration point (point B on the graph above). 
 

7. 

Release the handle. 

8. 

Slowly squeeze the handle through its entire movement. Confirm that the proper output is 
achieved. Refer to the graph above to see the LED output. 

9. 

Re-install main seal. 

 

 
 
 
 
 
 
 
 
 
 
 

ANALOG CALIBRATION (LEVER AND PNEUMATIC): 

A  FasMate  will  not  make  a  good  connection  if  cross-threaded  or  short-connected.  If  short-
connected,  the  piston  will  sit  near  or  at  rest  position,  and  the  voltage  will  be  smaller  than  the 
voltage for a good connection. If cross-threaded, the piston will be over-extended, and the voltage 
will be larger than for a good connection. To detect a good connection on an analog Sure Seal

TM

 

FasMate,  the  voltage  must  be  above  the  short-connect  threshold  voltage  (V

SC

)  and  below  the 

cross-thread  detection  voltage  (V

CT

).  This  calibration  procedure  is  a  guideline  for  determining 

these two voltages, but exact values depend on the user application.  
 

Lever Control (FNL) with Analog: 

1. 

Rotate red housing to desired location and lock in place 
with set screw. 

a. 

Red housing can be backed out one full turn from 
tight. (IDEAL POSITION FOR RED HOUSING IS 
TIGHT). 

2. 

Record the connector’s voltage at rest. The short-connect 
voltage  (Vsc)  will  be  approximately  0.8V  larger  than  the 
voltage  at  rest  but  may  vary  depending  on  your 
application. 

3. 

Squeeze handle fully. 

Note the voltage output at max travel. 

4. 

Fully insert connector into test piece port and release the lever. 

5. 

Verify that a good connection has been made. Record the output voltage. 

6. 

Repeat steps 3-5 several times and record the connector’s voltage. 

Use the distribution of 

values  to  determine  a  cross-thread  detection  voltage  (V

CT

)  that  is  suitable  for  your 

process, e.g. 2 standard deviations above the mean., or the largest voltage observed 
for a good connection minus some safety margin.

 

7. 

A good connection is indicated by the output voltage settling in the range between 

V

sc

 and 

V

CT

 

8. 

Once the range is determined, a 24VDC signal may be applied to pins 2 and 5 to provide 
red/yellow/green LED indication of connection quality. 
 

* When using Analog, please note that the shielded cable improves noise (single termination); 0-
10VDC is used over operational range of the sensor. 
 
Each time the connector is actuated, the threads can grip in a slightly different position. Therefore, 
a range needs to be set during the calibration stage. It is suggested to try and short connect it 
several times after the range has been set to ensure the range rejects bad connections. If the 
connection falls outside of this range, the system can be setup to alert operators. 
 
 
 
 
 
 
 
 

CALIBRATION POINT 

LINE UP GROOVE 

ON COLLETS WITH 

THIS INNER FACE 

Summary of Contents for FN Series

Page 1: ...nts its products against defects of workmanship and or material for 12 months from the date of the sale by FasTest Inc This warranty is void if the product is misused tampered with or used in a manner that is not in accordance with FasTest Inc recommendations and or instructions FasTest Inc is not liable for consequential or other damages including but not limited to loss damage personal injury or...

Page 2: ...STEPS 3 6 BEFORE STARTING CALIBRATION Note Point A1 is a preset distance from the rest position A As the shaft is extended from rest it will begin flashing yellow within the good zone A good connection is only indicated when the shaft retracts from beyond the upper limit B If a good connection is made and it s just to the right of Point A1 it could travel through point A1 once test pressure is int...

Page 3: ...t a good connection on an analog Sure SealTM FasMate the voltage must be above the short connect threshold voltage VSC and below the cross thread detection voltage VCT This calibration procedure is a guideline for determining these two voltages but exact values depend on the user application Lever Control FNL with Analog 1 Rotate red housing to desired location and lock in place with set screw a R...

Page 4: ...st voltage observed for a good connection minus some safety margin 7 A good connection is indicated by the output voltage settling in the range between Vsc and VCT 8 Once the range is determined a 24VDC signal may be applied to pins 2 and 5 to provide red yellow green LED indication of connection quality When using Analog please note that the shielded cable improves noise single termination 0 10VD...

Page 5: ...w pressure to remove the pressure piston The spring and actuator are located behind that 4 Remove o ring from pressure piston and replace 5 Install new spring and actuator 6 Coat outside of o ring with petroleum jelly 7 Push pressure piston back inside red housing Press in as squarely as possible 8 Apply Loctite 242 on screws and secure new PCA module tighten to 5 in lbs 8 Re install red housing o...

Reviews: