ICON CALIBRATION AND REBUILD INSTRUCTIONS

 

 

    Roseville, MN 

     Ph: 1-800-444-2373 
     Fax: 651-645-7390 

     www.fastestinc.com 

                                                                                                                                                                                                                                                                                   WP158 Rev B, 03/13/2020  
 

 

        

WIRING DIAGRAM: 

 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 

 
SSR MODULE CALIBRATION (LEVER HANDLE TYPE ONLY): 

Sure Seal™ 

enabled connectors need to be calibrated to each application. 

The FasMate con-

nector retains stored limit(s) even when power is removed. 

Due to the fine sensor resolution 

and variations in seal height, limits may need to be set each time seals are replaced, or the con-
nector is re-built. 

1. 

Rotate the red, back body to the desired location and lock it in place with the set screw. It 
can be backed out up to one full turn. 

2. 

Remove the main seal as shown in WP119. 
 

STOP! READ STEPS 3-6 BEFORE STARTING CALIBRATION. 

 

 

 
Note: Point A1 is a preset distance from the rest position (A). As the shaft is extended from 
rest, it will begin flashing yellow within the good zone. A good connection is only indicated 
when the shaft retracts from beyond the upper limit (B). If a good connection is made and 
it’s just to the right of Point A1, it could travel through point A1 once test pressure is intro-
duced, and the light will change from green to flashing yellow. Cancel the test, reconnect, 
and try again. 

 
 
 

The input is asserted by applying 24V. This can be accomplished by pressing the button 
on a FasTest Programming tool, or by using a 24V PLC signal or other 24V logic output.  

3. 

Flash input 4 times quickly to enter programming mode. Connector will flash 3 times indi-
cating programming mode. 

Note: If the first calibration point is not set within about 30 

seconds, the connector will return to operational mode.

 

4. 

Do not apply pressure to the handle.

 Hold input line high until indicator begins to flash, 

about 2 seconds. The first calibration point will be recorded when the input is released.  
 

 
 

Pinout/Standard M8 Cables 

Pin Number 

Wire Color 

Description 

BROWN 

24 VDC 

WHITE 

CALIBRATION 

BLUE 

GROUND 

BLACK 

NC 

GREY 

SSR CONTROL A 

PINK 

SSR CONTROL B 

Pinout/Standard M8 Cables 

Pin Number 

Wire Color 

Description 

BROWN 

24 VDC 

WHITE 

LED GREEN 

BLUE 

GROUND 

BLACK 

ANALOG OUTPUT 

GREY 

LED RED 

PINK 

LED RETURN 

STEPS 3-6 MUST BE COMPLETED WITHIN 30 SECONDS 

CV04SSR Pinout 

CV04SSR Wiring Diagram 

CV04ANA Pinout 

CV04ANA Wiring Diagram 