7
4. Specifications
4.1 Drive Specifications
Type
Drive Method
Input Voltage
Operate
Operate
Reserve
Reserve
Condition
Function
I/O
Temp.
Humidity
Vib. Resist.
Resolution(P/R)
Max. Frequency
LED Display
STOP Current
Pulse Input Method
Rotational Dir.
Speed/Position
Commamd
Input Signals
Output Signals
Alarm Function
EzStep-BD-42-S/M/L
EzStep-UD-42-S/M/L
PWM drive with 32bit DSP
24 VDC 10%
0 ~ +50
-20 ~ +70
35~85% RH (Non condensing)
10~90% RH (Non condensing)
0.5G
500~50,000 (Set by RS232C Communication)
Default : 10,000
500 KHz (Duty 50%)
Step-Out, Over-Current, Over-Heat, Over-Voltage, Power,Motor Connection
Power Status(Green), Alarm Status(Red)
CW Rotation(Yellow), CCW Rotation(Orange)
10% ~ 100% (Set by RS-232C Communication)
Be setted to set value of STOP current after 0.1 second after motor
stop.
Default : 50%
1 Pulse / 2 Pulse (Set by RS-232C Communication)
1 Pulse: Pulse / Direction, 2 Pulse: CW / CCW
Default : 2 Pulse
CW / CCW (Set by RS232C Communication)
Used when changing the direction of motor rotate.
Default : CW
Pulse train input (Photocoupler Input)
Photocoupler Input : Motor Free/Alarm Reset
Photocoupler Output : Alarm, Run/Stop
EzStep-BD-56-S/M/L
EzStep-UD-56-S/M/L
Summary of Contents for Ezi-STEP
Page 1: ......
Page 2: ...2 Fastech Co Ltd Table of Contents...
Page 8: ...8 Fastech Co Ltd 4 2 Drive Dimension mm...
Page 9: ...9 4 3 1 Bipolar Series 4 3 1 1 Bipolar 42mm 4 3 Motor Specifications Unit mm...
Page 10: ...10 Fastech Co Ltd Unit mm 4 3 1 2 Bipolar 56mm...
Page 11: ...11 Unit mm 4 3 2 Unipolar Series 4 3 2 1 Unipolar 42mm...
Page 12: ...12 Fastech Co Ltd Unit mm 4 3 2 2 Unipolar 56mm...
Page 13: ...13 5 Motor Torque Characteristics 5 1 Bipolar Motor...
Page 14: ...14 Fastech Co Ltd 5 2 Unipolar Motor...
Page 25: ...25 Alarm Output Run Stop Output 10 2 Output signals...
Page 26: ...Fastech Co Ltd 26...
Page 27: ...27...
Page 28: ......