www.fastech-motions.com - 19
18.5 Pulse Input Selection
18.6 Alarm Reset Input Selection
18.7 Alarm Output Selection
18.8 Run/Stop Output Selection
18.9 Motor Number, Motor Coils Current
As the Pulsed inputs, a user can choose One-pulse-mode(Pulse/Dir) or two-pulse-mode(CW/CCW).
Select a desired pulse mode by pressing in
button on Ezi-STEP BT Setting screen.
Input method of Motor Free/Alarm Reset can be selected. Select a desired method by pressing in
button on Ezi-STEP BT Setting screen.
Alarm signal output method can be selected when error happens. Select a desired method by pressing in
button on Ezi-STEP BT Setting screen.
Run/Stop output method can be selected that indicate the motor running status. Select a desired method by
pressing in
button on Ezi-STEP BT Setting screen.
This parameter can not be changeable. The information of Motor Number is needed for A/S of drive.
Press button to save the value selected into the drive.
※ The default factory setting is two pulse input mode(CW/CCW).
Press button to save the value selected into the drive.
※ The default factory setting is Nomal.
Press button to save the value selected into the drive.
※ The default factory setting is Nomal.
Press button to save the value selected into the drive.
※ The default factory setting is Nomal.
※ Caution : When you select
‘
Inverse
’
:
It can be
‘
Motor Free
’
status when power is applied to Ezi-STEP BT during Signal Connector(CN2)
is not connected. The power LED(green) is flash to show the status of
‘
Motor Free
’