www.fastech-motions.com - 10
11. Notes on Installation
1) Ezi-STEP BT is designed for indoor use only.
2) The ambient temperature of the room should be 0℃~50℃.
3) If the temperature of the product case is higher than 50℃, radiate heat of the
outside to cool down.
4) Do not install Ezi-STEP BT under direct rays, near magnetic or radioactive objects.
42
mm
Model name
Length(L)
42S
34
42M
40
42L
48
42XL
60
□
42
0
4-31
±0.2
0.1
4.5
±0.1
Ø
22.0
-0.05
0
+1
L+33.9
±1
L
±1
57
A
A
1.8
±0.2
20
±0.2
24
±0.5
Ø
0.075
A
4-M3 DP4.5
Ø5
-0.01
1
0
0.025
86
mm
Model name
Length(L)
86M
78
86L
117
86XL
155
56
mm
Model name
Length(L)
56S
46
56M
55
56L
80
A
□
86
±0.5
4-69.5
±0.2
1.6
±0.2
2-25
±0.3
±1
Ø0.076
0.05
A
0.076
Ø73
-0.05
0
4-Ø6.5
0
THRU
+0.3
L+46
±1
L
±1
10
±0.5
Ø14
-0.013
0
2-13
-0.1
0
A
37
100.5
A
□
57.15
±0.25
4-47.14
±0.2
1.6
±0.25
15
±0.2
±0.5
Ø
0.075
0.025
0.1
4-Ø5
0
THRU
Ø
38.1
-0.039
5.8
±0.1
0
+0.3
L+36
±1
L
±1
73.5
5
±0.25
Ø6.35
-0.01
3
0
A
20
A
10. Dimensions of Motor [mm]