9
baud rate not shown, type the baud rate in the box next to 115200 (e.g., type 128K as 128000), and hit the
tab key.
Do not hit enter.
Hitting enter will exit the program. If the baud rate changes after you tab, move to
the next box down and try again. Continue moving down until the baud rate stays the way you want it. Now
note the standard PC baud rate to the left of the box you ended on. You will select this standard baud rate to
set up your com ports, and the baud rate you require will be substituted. If you receive an error message
stating that the maximum baud rate was exceeded, change the Clock Divisor to 1 and try again.
INPUT FREQUENCY
This is the calculated frequency required to generate the baud rate requested. When you click OK on the
Fastcom Serial Settings page, this frequency is sent to the clock generator and the new baud rates will be
available.