background image

 

Page 24  

FBN Doc #: FBN-0098_03v12p4

 

5.5.2 Maintenance - Reboot 

This page allows the user to reboot either the local or the remote 

radio terminal, by clicking on “Reboot”. 

 

 

Figure 31  - Reboot page 

 

 

Figure 32 - Unit rebooting

 

 

 

Summary of Contents for Liberator-V100

Page 1: ...1 FBN Doc FBN 0098_03v12p4 Fastback Networks 2460 N First St Suite 200 San Jose CA 95131 U S A Sub10 Systems Ltd Ash House Canal Way Kingsteignton Newton Abbot Devon TQ12 3RZ UK Liberator V100 V1000 U...

Page 2: ...Type User Manual Project Liberator V100 V1000 Date 20 July 2015 Title V100 V1000 Installation User Manual Document Number FBN 0098_03v12p4 Version Date Description 03v01 17 Dec 2014 Release 02 01 03 0...

Page 3: ...to order as additional parts 10 4 Installation 11 4 1 Terminal installation 11 4 2 Grounding 11 4 3 Alignment Procedure 12 4 4 Factory Defaulting a Terminal 14 5 Web Management Interface 15 5 1 Login...

Page 4: ...gainst lightning strikes It is the user s responsibility to ensure that the equipment is installed in accordance with national regulations USA Articles 810 830 of the National Electric Code ANSI NFPA...

Page 5: ...V100 and up to 1Gbps V1000 Licence free operation The system has been approved and can be operated in many countries without needing an individual regulatory licence for each link System administrati...

Page 6: ...Page 6 FBN Doc FBN 0098_03v12p4 2 2 Ethernet switch Each radio terminal includes an Ethernet switch Figure 2 Network layers of the V100 V1000 system...

Page 7: ...plug version showing parts for one end of the link NOTE In the USA the PoE power supply may be ordered separately from the rest of the link kit Please check the ordering guide for more information 2...

Page 8: ...PoE supply conforms to PoE specifications It is recommended that the Sub10 Systems PoE power injector should always be used to power the Liberator V100 V1000 The installer must use a mains voltage su...

Page 9: ...mm to 115 mm diameter 2 3 5 Ice Bridge Sun Shield The ice bridge protects the terminal against rain snow and ice 2 3 6 RJ45 Seal Kit The RJ45 seal kit connects the Ethernet tail from the ODU to a CAT...

Page 10: ...s onto the back of the ODU 2 4 2 Surge Arrestor The surge arrestor is placed between the ODU and the Ethernet cable connecting to the PoE 2 4 3 Wall mount bracket The wall mount bracket allows the ali...

Page 11: ...1 1 Terminal installation Polarization It is important to install the terminal on the bracket with the same orientation antenna polarization at both ends of the link Figure 14 V1000 backhousing with...

Page 12: ...chieves fast accurate alignment Figure 16 Adjustment screws Use a 6mm tool to adjust the scope Measure the Voltage via the DC port Power Level Alignment Use the Voltage vs RSSI graph to check the sign...

Page 13: ...v 03v12p4 Page 13 FBN Doc FBN 0098_03v12p4 Figure 18 Alignment voltage vs RSSI see Appendix A 2 3 Follow the scanning pattern example in Figure 19 to find the peak voltage on the voltmeter Figure 19 S...

Page 14: ...c FBN 0098_03v12p4 4 4 Factory Defaulting a Terminal To reset to factory default short circuit the Alignment interface and then remove and re apply the short 4 times Figure 20 Reset Sequence using the...

Page 15: ...FBN 0098_03v12p4 5 Web Management Interface 5 1 Login Page Figure 21 Login Page The default login account has full Maintenance Level privileges Default IP address Terminal A 192 168 0 21 Default IP a...

Page 16: ...the interfaces are up otherwise they will be YELLOW for acquiring or RED for down The alarm bars are highlighted in GREEN YELLOW or RED depending on the status of each alarm The menu on the left side...

Page 17: ...antenna port inside the ODU Vector Error dB A measure of the signal quality MWU Temp Celsius Operating temperature of the microwave unit inside the radio Air Frame Error Ratio error rate over the air...

Page 18: ...Page 18 FBN Doc FBN 0098_03v12p4 5 4 Administration 5 4 1 Administration QoS The QoS has 8 priority queues Figure 24 QoS settings...

Page 19: ...low the transmit power to be dynamically adjusted by the radio in response to changing propagation conditions e g rain fade The Modulation Mode can be used to change modulation mode between fixed QPSK...

Page 20: ...Page 20 FBN Doc FBN 0098_03v12p4 5 4 3 Administration Management 5 4 3 1 Administration Management IP Configuration This page is used to configure the Ethernet interface Figure 26 IP Configuration...

Page 21: ...NMP The SNMP Configuration Page is used to configure the SNMP Agent Figure 27 Configuring SNMP The SNMP Agent is compatible with SNMPv1 SNMPv2c and SNMPv3 5 4 4 Administration Installation When Alignm...

Page 22: ...age 22 FBN Doc FBN 0098_03v12p4 5 4 5 Administration Security Users This page shows the users who are registered to use the system together with their privilege level Role Figure 29 Security Users Pag...

Page 23: ...iberator V100 V1000 User Manual Rev 03v12p4 Page 23 FBN Doc FBN 0098_03v12p4 5 5 Maintenance 5 5 1 Maintenance Firmware Upgrade This page is used to upgrade the firmware Figure 30 Firmware Upgrade pag...

Page 24: ...24 FBN Doc FBN 0098_03v12p4 5 5 2 Maintenance Reboot This page allows the user to reboot either the local or the remote radio terminal by clicking on Reboot Figure 31 Reboot page Figure 32 Unit reboo...

Page 25: ...Liberator V100 V1000 User Manual Rev 03v12p4 Page 25 FBN Doc FBN 0098_03v12p4 5 6 Logout This page allows the user to Logout securely Figure 33 User Account Logout Page...

Page 26: ...FBN 0098_03v12p4 A TECHNICAL INFORMATION A 1 Specifications A 1 1 Physical size of ODU terminal All dimensions are in millimetres Figure 34 Dimensions of radio terminal in mm 224 95 114 68 162 131 224...

Page 27: ...enna gain 35 6 dBi nominal gain at 58GHz Wind load 160 km h operating and 200 km h survival QoS 8 queues using VLAN PCP bits current software Network management SNMP v1 v2c v3 Interface 1000 Base T Dr...

Page 28: ...TION B 1 1 FCC statement B1 1 1 Regulatory Statements and Labels The Liberator V1000 and Liberator V100 have been certified as compliant with the FCC Rules under Part15 255 and have been assigned the...

Page 29: ...ng Electric Magnetic and Electromagnetic Fields up to 300 GHz see www icnirp de B 1 2 1 Human Exposure to Non Ionising Radiation in Europe In Europe the assessment of the levels of non ionising radiat...

Page 30: ...support fastbacknetworks com C 2 Sales General Product Information Customers please visit the Fastback Networks website http www fastbacknetworks com Or Contact info fastbacknetworks com Fastback Net...

Reviews: