background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast Food Systems Limited 

Manufacturer & Distributor of Catering Equipment 

Unit 1 Headley Park 9 Headley Road East 

Woodley Reading Berkshire RG5 4SQ 

Tel: 0118 944 1100 Fax: 0118 944 0350 

Email: [email protected] 

Website: www.fast-food-systems.com 

ISSUE 10: 14.06.17 

Model Number……………………………… 

Order ID/Job No…………………………… 

Machine serial number…………………… 

Date of Manufacture ……/………/……… 

Date of delivery……/………/…… 

Date of commissioning……/………/……

 

 

 

Summary of Contents for VI3TFC

Page 1: ...ion Heat lamp heat from above Adjustable lane guides to different widths Lane Labels available for quick reference both loader and server Only top heat for all three tiers Easy to clean removable part...

Page 2: ...e 1030mm 800mm 800mm Model VI003G Dimensions Height Width Depth Machine 1030mm 800mm 800mm Weight Electrical Running Amps Connection Type International Option 1 phase 50HZ AC 230v 2 4Kw 10 4 Amps BSCH...

Page 3: ...designed to hold burgers and other cooked wrapped or boxed foods ready for service Assembly Instructions Remove all packing from the unit Peel off all protective plastic covering from metal Wash all...

Page 4: ...ch as Sheila Shine and a soft lint free cloth Note Do NOT use abrasive cleaners or pads and do NOT bleach Wipe ceramic elements only when they are cold with a damp clean cloth Do NOT touch or clean qu...

Page 5: ...3 Tier Food Chute Exploded Diagram...

Page 6: ...t breaker at mains supply board is in i e ON Replace switches One or all the green switches do not illuminate 2a Switch es in OFF position 2b Switch faulty 2aa See Section 1 2bb Switch on Replace swit...

Page 7: ...PER SET 3 MF3001200 Strain relief bush 1 MF354Z 2 Pole 5amp term block TB06 9 MFOHSL01 High temperature sleeving 3 MF605 649 Grommet 4 MFCOMMON1 Label 5 140mm x 53mm 1 MFEUROCONVERT Euro to UK conver...

Page 8: ...The lamps whilst being a high output unit are fragile They must be handled with care and they must be kept clean Guards are fitted to prevent dirt and grease contacting the bulbs Grease from fingers w...

Page 9: ...Wiring Diagram...

Page 10: ...t code VI3TFC Customer name Date of delivery Machine serial number Damage comments Please indicate on the picture where the unit is damaged Courier name Please cut this page out and post to Fast Food...

Page 11: ...ivery Claims for non delivery must reach the Company within 10 days from the date of dispatch All other claims must reach the Company within 7 days Damaged goods must be retained for inspection collec...

Page 12: ...months The following are NOT covered by warranty 1 Failure or breakdown caused by incorrect installation 2 Glass parts electric lamps or door seals 3 Adjustment or calibration of controls this is a r...

Page 13: ...NOTE...

Page 14: ...NOTE...

Page 15: ...NOTE...

Page 16: ...k 9 Headley Road East Woodley Reading Berkshire RG5 4SQ Tel 0118 944 1100 Fax 0118 944 0350 Email service fast food systems co uk Website www fast food systems com ISSUE 10 14 06 17 Model Number Order...

Reviews: