![Fast Flow Pumps Fast Flow 3 Operation And Maintenance Manual Download Page 13](http://html.mh-extra.com/html/fast-flow-pumps/fast-flow-3/fast-flow-3_operation-and-maintenance-manual_546103013.webp)
13
Impeller Replacement
Disassembly
1
.
Disconnect all hoses from the pump head
2.
Make certain there is no residual pressure in the hydraulic system
3.
Drain off any fluid by inver ng the pump head and clean.
4.
Place the pump head on a solid flat surface with adequate working space.
5.
Remove two upper frame bars
6.
Remove four bolts from pump & remove pump case
7.
Remove 2 bolts from impeller #4.
To reassemble simply reverse order of removal procedure and confirm impeller is centered in volute. ARer
reassembly is complete, hand spin the impeller with pump fully assembled. Impeller gap should have the
same clearance from impeller blade to housing. Tighten all impeller bolts equally with the same force-
pounds of torque. Check all pump frame bolts are installed and ghtened to torque spec before running
unit again.
Failing to follow these instruc ons closely may cause damage to the pump.