Fury RSW55
11
The drive motor will not advance or
back up when working.
Drive motor chain is broken.
Replace drive motor chain.
The pedal governor is damaged.
Replace the pedal.
The control switch is damaged.
Replace the switch.
The controller is damaged.
Replace the controller.
The electrodynamic vibration
equipment does not work.
Switch has malfunctioned.
Replace the switch.
The fuse has burnt out.
Replace the fuse.
Motor brush is damaged.
Replace motor brush.
Bearing is worn out.
Replace bearings.
Motor coil has burnt out.
Replace motor.
Motor has been overloaded.
Contact your local service center.
The electrodynamic vibration is too
large and the fuse sparks.
The electrodynamic vibration load
is too large, fuse is malfunctioning,
or there is a short circuit.
Contact your local service center.
The side brush or main brush works
but does not rise or fall.
The overload protection switch is
bumped, or the lifter is damaged.
Press the overload protection
switch, or replace the lifting motor,
Run time has shortened.
Batteries have worn out.
Replace batteries.
Battery charger has failed.
Replace charger or contact
service center.
Maintenance and Check-up Schedule
Interval
8 hours
80 hours
150 hours
500 hours
1500 hours
1 Check the battery voltage
2 Check the carbon brush of drive
motor
3 Check the carbon brush of fan
4 Check the condition of main brush
and side brooms
5 Check the cleaning of the filter
6 Check the dashboard
7 Check the tension of the drive belt