Fasep 2000 srl
Rev. 1.0
Videotronic V788.G3: User
’s Manual
05 october 2016
3-7
Fig. 56
: Distance
Fig. 57
: Width
7
MEASUREMENT AND CORRECTION OF UMBALANCE
7.1
Placing the wheel rim on the wheel balancer
7.1.1
Select the cone or flange suitable for the wheel to be balanced. Specific mounting instructions are delivered with each flange
G
NOTE:
the operation of centering and tightening of the wheel on the flanges is of basic importance for correct balancing.
Good results depend on proper performance of these procedures.
To accurately clean up the superficial ones of connection before whichever operation.
!
CAUTION:
Always make sure flanges are correctly locked on the motor shaft and wheel is correctly locked on the
flange being used.
7.2
Input of Rim Dimensions (external measuring system version)
for V65x, V64x, V55x-D (automatic input of all data)
G
NOTE:
AUTOSELECT function admit to choose automatic selection of balancing system (Dynamic, ALU-S1, ALU-S2)
MAIN MENU
Insert the distance (fig.56).
Insert the width (fig.57).
Summary of Contents for VIDEOTRONIC V788.G3