4.2
How to check the calibration of Wheel Balancer (USER)
ATTENTION
select mode
CAL USR
Press <+/-> to select
CAL TEST
Place a wheel on the flange.
Insert the distance measure (IN) (Fig.13).
Insert the diameter measure (DIA).
Execute the first wheel calibration launch using the
appropriate wheel spinner (Fig. 14).
NOTE:
ACC EL:
impress greater speed.
RED UCE:
reduce the speed.
GO OD:
the speed is corrected.
Turn the wheel until the writing
60 PUT
is displayed.
Apply a 60g adhesive weight on the internal side of the
wheel (Fig.15).
Execute the second wheel calibration launch.
Press
<FINE>
to see actual values. 60-0 (±3) is correct
result.
When all LED (left side) are lit, calibration weight must be
at exactly 6 o’clock.
If no, press
<FUNC>
to calibrate position.
Turn the wheel until the calibration weight is located at 6
o’clock.
Press
<SET>
to calibrate.
Press
<MODE/ESC>
to return to normal balancing mode.
NOTE
technical calibration
CAL TEC
is only available for qualified personnel.