Rev. 01 07/2022
Menu
"
F
": the "
F
" menu allows to set the engine operating hours before generating, for their saturation,
a Filter Alarm; press the
UP
button to go to the "
E
" menu, while the
DOWN
button will go to the "
t
" menu. With
the
ESC
key, you exit the Configuration Menu.
Use the
ENTER
key to enter the submenu for setting the saturation hours; with the
UP
and
DOWN
keys you
can choose between 10 possibilities (from 0 to 9) to which the times correspond as follows:
0:0 hours
(Default – alarm OFF)
1: 10 hours
2: 20 hours
3: 30 hours
4:40 hours
5: 50 hours 6: 60 hours
7: 70 hours
8: 80 hours
9: 90 hours
With the
ENTER
key, the filter duration hours are acquired and stored and you return to the "
F
" menu.
Pressing the
ESC
key returns to the "
F
" menu without saving the current setting.
"
E
"
menu
: the "
E
" menu allows to set the activation delay of the Gas Solenoid valve when the motor is
switched on (see Motor starting procedure); use the
UP
key to go to the "
A
" menu, while using the
DOWN
key
to go to the "
F
" menu. With the
ESC
key, you exit the Configuration Menu.
With the
ENTER
key you enter the submenu for setting the activation delay of the Gas solenoid valve; with the
UP
and
DOWN
keys you can choose between 10 possibilities (from 0 to 9) to which the times in the fol-
lowing table correspond:
0: 1 sec.
1: 10 sec.
2: 20 sec. (default)
3: 30 sec.
4: 40 sec.
5: 50 sec. 6: 60 sec.
7: 70 sec.
8: 80 sec.
9: 90 sec.
With the
ENTER
key, the selected delay is acquired and stored and you return to the "
E
" menu.
Pressing the
ESC
key returns to the "
E
" menu without saving the current setting.
“
A
”
menu
: the "
A
" menu allows setting the temperature limits to which minimum and maximum speed
correspond in automatic mode; press the
UP
button to go to the "
I
" menu while using the
DOWN
button to go to
the "
E
" menu. With the
ESC
key, you exit the Configuration Menu.
Press
ENTER
to enter the submenu for selecting the temperature limit to be set; with the
UP
and
DOWN
keys it
is possible to select the lower temperature limit indicated by the letter "
L
" (Low) or the upper temperature limit
indicated by the letter "
H
" (High); press
ENTER
to enter the relative temperature selection submenu, and return
to menu "
A
" with the
ESC
key.
Submenu
“
L
”:
with the
UP
and
DOWN
keys you can choose between 4 possibilities (from 1 to 4) to which the
temperatures correspond as follows:
1: 25°C
2: 30°C (default)
3: 35°C
4: 40°C
Press
ENTER
to acquire and store the selected temperature level and return to the "
L
" menu.
Press the
ESC
key to return to the "
A
" menu without saving.
Sub-menu
"
H
": with the
UP
and
DOWN
keys you can choose between 6 possibilities (from 1 to 6) to
which the temperatures correspond as follows:
1: 45°C
2: 50°C (default)
3: 55°C
4: 60°C
5: 65°C
6: 70°C
With the
ENTER
key, the selected temperature level is acquired and stored and you return to the "
H
" menu.
Press the
ESC
key to return to the "
A
" menu without saving.
Restore default settings
To restore the default configuration of the controller, enter the Configuration Menu (first menu level) and keep
the SW3 and SW4 keys pressed simultaneously for at least 3 seconds; the exit from the Configuration Menu
with simultaneous temporary display of the letter "d" indicates the successful restoration.
This operation involves restoring the default conditions for:
the 8 speeds of non-automatic operation
the starting speed
the activation delay of the gas valve when the fan is switched on
the delay in switching off the motor
the hours of filter saturation (Alarm disabled)
Automatism (disabled).
If the alarm condition occurs when the Automatic mode is deactivated, only the anomaly related
to point 1 (NTC probe not detected or temperature measurement below the minimum
permissible limit) is signaled and managed, and in particular:
if the anomaly occurs with the motor running, then the motor and the light are switched off
and the display shows the alarm code represented by the letter "c" flashing;
after the motor and light have been switched off, any light and motor ignition commands are
ignored and the display continues to show the letter "c" flashing ;
if the alarm condition ends before the power supply to the controller is removed, the active
functions are restored before the alarm occurs (unless these functions have been disabled
from the keypad or remote control after the alarm event occurs same); with the alarm retur-
ned, the display no longer shows the letter "c" flashing;
if with active alarm the Automatic Mode is selected (by pressing the SW3 key of the key-
board for about 2 seconds, as already specified above) the automatism will be inhibited,
but it will be possible to use the controller to switch the light on / off, switch on / off the
motor and change its speed using the appropriate keyboard commands; in this case the di-
splay shows the letter "c" alternating with the indication of the current speed.
Note
: w ith NTC probe alarm in progress and in the presence of a possible filter alarm,
the display alternately shows the alarm code (represented by the letter "c" or by the letter "E",
as specified above) and the letter "F" for signaling active filter alarm.
Reset filter alarm
When the motor is switched off and the configuration menu is not active, pressing the SW2 key
on the keyboard for about three seconds resets the filter usage hours counter and any filter
alarm.
Regulator configuration
Configuration menu
With motor off, access the Configuration Menu by keeping the "SW1" key pressed for at least 3
seconds. The keys of the keyboard allow navigation in the Configuration Menu as follows:
-
SW1
key ("
ENTER
" ): Confirm value set or Input in submenu.
-
SW2
key ("
ESC
" ): Output w ithout saving the set value or ascent in the submenu
tree.
-
SW3
key ("
UP
" ): Value increase during setting or scrolling of the active submenu
items.
-
SW4
key ("
DOWN
" ): Value decrease during setting or scrolling of the active subme-
nu items.
"P" menu
: the "
P
" menu is the entry point in the Configuration Menu and allow s set-
ting the starting, minimum and maximum speed; use the
UP
button to switch to the "
T
" menu.
With the
ESC
key, you exit the Configuration Menu.
Use the
ENTER
key to enter the submenu to set the starting speed "
b
" (boost). The motor mo-
ves to the minimum speed that can be associated with this parameter (it should be noted that
this speed, depending on the type of load applied, may not be sufficient to start the engine, in
which case press the
UP
key to increase it when the engine starts). The speed can be changed
to the desired point with the
UP
and
DOWN
keys.
With the
ENTER
key, the current speed is acquired as the starting speed and the minimum "
L
"
speed setting submenu is entered (Low); with the
UP
and
DOWN
keys the motor speed can be
brought to the desired minimum level; it is not possible to select a speed greater than that
chosen for the starting speed.
With the
ENTER
key, the current speed is acquired as minimum speed (1) and the submenu for
setting the maximum speed "
H
" (High) is entered; the motor goes to the maximum speed (8)
that can be changed to the desired point with the
UP
and
DOWN
keys.
With the
ENTER
key, the current speed is acquired as the maximum speed (8); the
intermediate speeds are automatically calculated; the 8 speeds plus the inrushing speed are
memorized and you return to the "
P
" menu.
Pressing the
ESC
key in the submenus "
b
", "
L
" , and "
H
" returns to the "
P
" menu w ithout
saving any speed settings.
Menu
"
t
" : the "
t
" menu allow s to set the delay for the actual sw itching off of the motor
upon receiving the switch-off command (see engine shutdown procedure); use the
UP
key to go
to the "
F
" menu while using the
DOWN
key to switch to the "
P
" menu. With the
ESC
key, you
exit
the
Configuration
Menu.
Press
ENTER
to enter the submenu for setting the switch-off delay; with the
UP
and
DOWN
keys
you can choose between 10 possibilities (from 0 to 9) to which the times correspond as follows:
0: 0 sec. 1: 20 sec. (default) 2: 40sec.
3: 60 sec.
4:80 sec.
5:100sec.
6: 120 sec. 7: 140 sec.
8: 160 sec.
9: 180 sec.
With the
ENTER
key, the selected delay is acquired and memorized, and you return to the "
t
"
menu.
Pressing the
ESC
key returns to the "
t
" menu without saving the current setting.
Regulator installation
After removing the cover, make the necessary holes on the box for the passage of the cables,
the cable glands and of the temperature probe. Then set the box to the desired support and
connect to the terminal block on the board respecting the connection scheme. (Note: If the
motor used in the installation has a metallic chassis, it is recommended to connect this to the
one of the two terminal blocks on the board. The second terminal then will be connected to
the earth by the eletricity grid). Connect the temperature probe to CN1 connector on the
board.
After making the connections, provide supply to the regulator. This will remain in low power
mode (standby) until will be activated outputs or will enter to the Configuration menu.
Check the outputs correct operation using the special keys on the front panel.
Then close the cover using the screws: the device is ready for use.