Configure  the  module  to  the  EtherCAT  network:  find  the  FieldBus  Modules  in 

the  toolbox  on  the  right,  find  the  module  model  icon  and  double-click  to  add  it  to 

the  network 

The PLC goes to online mode, right-click the master device, and write the node address of the 

slave device 

Variable mapping: Select the configured node in the I/O mapping, fill in the name of the 

variable, and the configuration is complete! . 

Summary of Contents for FNI MPL-302-105-M

Page 1: ...Page 1 of 16 FNI MPL 302 105 M IP 67 Module User Manual...

Page 2: ...rity Notes 4 2 4 Resistance to Corrosive Substances 4 3 Getting Started Guide 3 1 Module overview 5 3 2 Mechanical connection 6 3 3 Electrical connection 6 4 Technical data 4 1 Size 8 4 2 Mechanical d...

Page 3: ...can also be displayed numerically in parentheses 1 Step 1 2 Step 2 Number Decimal numbers are displayed without additional indicators eg 123 Hexadecimal numbers are displayed with an additional indica...

Page 4: ...intended use The manufacturer s warranty coverage and limited liability statement do not cover damage caused by Unauthorized tampering Improper use Owner operator s obligations This device is an EMC...

Page 5: ...ndicator 3 Network port 2 4 Power outlet 5 DIP switch 6 Port 1 8 Port 5 9 Port 7 10 Port 6 11 Port 4 12 Port 2 13 Port Status Indicators 15 Port Identification Board 16 Power input port 17 Module indi...

Page 6: ...Us 0V 4 Ua 24V FE Functional ground FE Notes 1 If possible supply sensor module power and actuator power separately Total current 9A The total current of all modules is 9A even when daisy chaining the...

Page 7: ...t guidelines of EN61131 2 Type 2 2 The maximum output current of pins 2 and 4 is 2A The total current of the module is less than 9A 3 Unused I O port sockets must be covered with end caps to meet IP67...

Page 8: ...interface L Code Male and Female Input port output port M12 A Code 8 female Size W H D 65mm 222mm 25 8mm Installation type 2 Through Hole Mounting Ground Bus Accessories M4 weight About 670g 4 3 Oper...

Page 9: ...on protocol ECT Communication Protocol Module Status LED State Function US Green Power is OK Red Greater than 30V or less than 11V Flashing red less than 18V UA Green Power is OK Red Greater than 30V...

Page 10: ...Page 10 of 16 Red light double flash Application monitoring timeout...

Page 11: ...current 2 Closure Port configured as output short circuit between Pin1 and 3 2 Yellow The status of Pin2 input or output is 0 2 Rred The state of Pin2 input or output is 1 2 Flashing red Port configur...

Page 12: ...wer off the device dial the code to the state before setting 5 1 2 Node address configuration The node address is assigned by PLC DIP address X100 4 X10 0 X1 0 Manual assignment of node address DIP ad...

Page 13: ...0 PIN4 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 1 PIN2 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 2 PIN4 short circuit status Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 3...

Page 14: ...NX1P2 Sysmac Studio Integrated ECT 1 Install the ESI file double click EtherCAT in the configuration and settings right click the master device select Show ESI library and select the ESI file in the...

Page 15: ...ight find the module model icon and double click to add it to the network 3 The PLC goes to online mode right click the master device and write the node address ofthe slave device 4 Variable mapping S...

Page 16: ...dix 6 1 Included materials 6 2 Order code FNI MPL contains the following components I O block 4 blind plugsM12 Ground bus Thread M4x6 20 tags 6 3 Ordering Information Product order code Order code FNI...

Reviews: