This manual describes as decentralized  input   and 
output modules for connection  to an industrial  network. 

Precautions! 

Installation and start-up may only be carried out  by 

trained and specialized personnel. A  qualified 
individual is one who is familiar with the 
installation and operation of the product and  has
the necessary qualifications to do so. Any  damage
caused by unauthorized operation or illegal  and 
improper use is not covered by the  manufacturer's
warranty. Equipment operators are responsible  for
ensuring that appropriate safety and  accident 
prevention regulations are  followed. 

2.3.

 

General

 security 

 Notes 

2.4. Corrosion 
resistance 

Debug and  check 

Before debugging, you should read the contents of the  user 

manual  carefully. 

The system cannot be used in applications where the   safety 

of personnel depends on the functionality of the  equipment. 

intended  use 

The manufacturer's warranty coverage and limited  liability 

statement do not cover damage caused  by: 

·

Unauthorized  tampering

·

Improper  use

·Owner/operator's

 obligations

This device is an EMC Class A product. This  device 

generates RF  noise. 

The owner/operator must take proper precautions when using 

this  equipment.  Use  only  a power  source  compatible  with 

this device and connect only approved  cables. 

Fault 

In  the  event  of  a defect  or  equipment  malfunction  that 

cannot  be  corrected,  the  equipment  must  be  taken  out  of 

operation to avoid possible damage from unauthorized   use. 

Intended  use  can  only  be  ensured  when  the  enclosure  is 

fully  installed.

-   -

-

-   -    -   -   -   -   -    -    -   -   -   -    -   -   -   -   -   -    -   -   -   -    -    -   -   -   -    -   -   -   -    -    -   -   -

-

-

-   -

-    - 

-   -

-   -

-   -  -   -

-   -

-   -  -   -

-   -

Precautions! 
FNI modules generally have good chemical and oil resistance 

characteristics. When used in aggressive media (e.g. high 
concentrations of chemicals, oils, lubricants and coolants 
(i.e. low water content)), these media must be checked 
before the corresponding application material compatibility 
confirm. If the module fails or is damaged due to this 
corrosive medium, no claim for defects can be claimed.

-  - -  - -  - 

-  - -  - -  - -  -  -  - -  - -  - -  - -  - -  - -  - -  -  -  - -  - -  - -  -  -  - -  - -  - -  - -  - -  - -  - -  - -  - -  -  -  -  - 

Dangerous voltage

 

- -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  - -  -  -  - -  - -  - -  - -  - -  - -  - 

Precautions! 

Disconnect all power sources  before using the equipment!

-  - -  - 

-  - -  - -  - -  -  -  - -  - -  - -  - -  - -  - -  - -  -  -  - -  - -  - -  -  -  - -  - -  - -  - -  - -  - -  - -  - -  - -  -  -  - -  - - 

Summary of Contents for FNI MPL-302-105-M

Page 1: ...Page 1 of 16 FNI MPL 302 105 M IP 67 Module User Manual...

Page 2: ...rity Notes 4 2 4 Resistance to Corrosive Substances 4 3 Getting Started Guide 3 1 Module overview 5 3 2 Mechanical connection 6 3 3 Electrical connection 6 4 Technical data 4 1 Size 8 4 2 Mechanical d...

Page 3: ...can also be displayed numerically in parentheses 1 Step 1 2 Step 2 Number Decimal numbers are displayed without additional indicators eg 123 Hexadecimal numbers are displayed with an additional indica...

Page 4: ...intended use The manufacturer s warranty coverage and limited liability statement do not cover damage caused by Unauthorized tampering Improper use Owner operator s obligations This device is an EMC...

Page 5: ...ndicator 3 Network port 2 4 Power outlet 5 DIP switch 6 Port 1 8 Port 5 9 Port 7 10 Port 6 11 Port 4 12 Port 2 13 Port Status Indicators 15 Port Identification Board 16 Power input port 17 Module indi...

Page 6: ...Us 0V 4 Ua 24V FE Functional ground FE Notes 1 If possible supply sensor module power and actuator power separately Total current 9A The total current of all modules is 9A even when daisy chaining the...

Page 7: ...t guidelines of EN61131 2 Type 2 2 The maximum output current of pins 2 and 4 is 2A The total current of the module is less than 9A 3 Unused I O port sockets must be covered with end caps to meet IP67...

Page 8: ...interface L Code Male and Female Input port output port M12 A Code 8 female Size W H D 65mm 222mm 25 8mm Installation type 2 Through Hole Mounting Ground Bus Accessories M4 weight About 670g 4 3 Oper...

Page 9: ...on protocol ECT Communication Protocol Module Status LED State Function US Green Power is OK Red Greater than 30V or less than 11V Flashing red less than 18V UA Green Power is OK Red Greater than 30V...

Page 10: ...Page 10 of 16 Red light double flash Application monitoring timeout...

Page 11: ...current 2 Closure Port configured as output short circuit between Pin1 and 3 2 Yellow The status of Pin2 input or output is 0 2 Rred The state of Pin2 input or output is 1 2 Flashing red Port configur...

Page 12: ...wer off the device dial the code to the state before setting 5 1 2 Node address configuration The node address is assigned by PLC DIP address X100 4 X10 0 X1 0 Manual assignment of node address DIP ad...

Page 13: ...0 PIN4 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 1 PIN2 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 2 PIN4 short circuit status Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 3...

Page 14: ...NX1P2 Sysmac Studio Integrated ECT 1 Install the ESI file double click EtherCAT in the configuration and settings right click the master device select Show ESI library and select the ESI file in the...

Page 15: ...ight find the module model icon and double click to add it to the network 3 The PLC goes to online mode right click the master device and write the node address ofthe slave device 4 Variable mapping S...

Page 16: ...dix 6 1 Included materials 6 2 Order code FNI MPL contains the following components I O block 4 blind plugsM12 Ground bus Thread M4x6 20 tags 6 3 Ordering Information Product order code Order code FNI...

Reviews: