Operation Manual
FarSounder, Inc.
F31552 (Rev. 2.6.1)
Page 5 of 56
Warning
Do not open the transducer module. Injury or death may result. There are no user serviceable
parts inside.
The Transducer Module has a single underwater matable connection. This connector is used to connect the
Transducer Module to the Power Module via FarSounder's Transducer Module Connection Cable. When
properly installed, the face protrusion and the rear connector should be at the 12 o'clock position.
Figure 3. Rear view of Transducer Module. Apply o-ring grease to only the rubber base of the connetor pins.
The connector can be connected dry or underwater. Before connecting, a small amount of silicon O-ring
lubricant should be put around the black rubber portion of the pins on the Transducer Module's mating
connector. If connecting underwater, lubricant may not be necessary.
Warning
Do not get the lubricant on the metal conductor pins.
The wet end connector should not be left unconnected while wet or underwater for extended periods of
time. A Connection Cable End Cap (F24557) is supplied as standard for use during transport/installation
and extended periods of unconnected wet or underwater use.
Installation
The Transducer Module has been designed to allow for a simple, one cable connection to the rest of the
sonar hardware. Twelve holes are located around the Transducer Module's flange to allow for mechanical