Inspect product box and unit for any shipping
damage.
Save product box in the event the unit needs to
be shipped in the future. Shipping the unit in a
generic box may void warranty.
OVERVIEW:
Be sure to use high quality cables for
both sources and output signals. All video and High
Definition scan rates are processed and converted to
the selected output rate and format. VESA (PC) rates
are pass-through only.
1. S-VIDEO INPUT:
Use for video games, satellite
and DVD sources if Component or DVI outputs are
not available.
2. DVI INPUT:
Use with satellite or DVD sources.
The processor is always monitoring the DVI input and
output status and provides information on the front
panel LCD. The LCD status screens are:
DVI:
Input signal is supported
NO INPUT:
No signal is detected.
VERIFYING OUT-LINK:
DVI connection to the
display has been interrupted.
DVI PASS-THROUGH:
A VESA rate has been
detected and sent to the output unprocessed.
RATE NOT SUPPORTED:
A VESA or non-video rate
has been detected but the selected output is analog
RGB or YPrPb.
NOTE #1:
Input type is auto-detected. Supported
video rates for processing are 480i/480p, 576i/576p,
720p/1080i @ 50Hz/60Hz. VESA rates are sent to
PASS-THROUGH only.
(Continued next page)
2 5 6 9
NOT ACTIVE
10
1
3 4 7 8 11 12
8
LEVEL 3 WARNING
EXCESSIVE TEMPERATURE
The internal temperature has reached the
maximum limit. This warning will display for five
seconds, then the unit will shut down and cannot be
powered up by the Power button or Remote.
Unplug the unit from the wall power to reset.
Once the unit has cooled down, normal operation
returns.
MOUNTING
UNPACKING
Shelf or rack mountable (rack kit included).
Note #1:
EXCESSIVE HEAT MAY CAUSE THE PRO-
CESSOR TO MALFUNCTION OR SHORTEN PRODUCT
LIFE. Follow regular installation rules for proper
ventilation.
Note #2:
Be sure rack location has adequate
ventilation. Allow a minimum of 1RU rack space
(1.75”) above and below unit for ventilation.
Do not mount above power amps or other
equipment that may generate excessive heat.
OVERHEAT WARNING
To help insure long term operation, the processor has
a built in heat sensor to monitor the internal tem-
peratures of the unit . There are three warning
levels that appear on the front panel LCD.
LEVEL 1 WARNING
HIGH TEMPERATURE
The internal temperature is exceeding optimum
operating temperature. Steps should be taken to
improve ventilation.
LEVEL 2 WARNING
HIGH TEMPERATURE
The internal temperature is close to the maxi-
mum limit. Immediate steps should be taken to
improve the installation ventilation and obtain an
optimum operating temperature.